41
Internal Error 2
Communication error (some PCB has failed or is disconnected (this PCB will show as N/A in menu --> Infor
-
mation --> Software versions) or error/noise was detected on communication wires)
Clean Air Filters
The message informs you that the item "Elapsed Time" in the "Fixture Information" menu is at 0 value. Clean
air filters and reset this counter.
Overheated
The LED engine is overheated and light output is closed.
White 1 Short Error (White 2 Short Error/ White 3 Short Error/ White 4 Short Error)
Some white LEDs in the light source have short circuit or are disconnected.
White 5 Short Error (White 6 Short Error/ White 7 Short Error/ White 8 Short Error)
Some white LEDs in the light source have short circuit or are disconnected.
Base Fan 1 Bad/ Base Fan 2 Bad
One or both fans in the fixture base are disconnected from their control PCB or are faulty and has to be replaced. .
Suction LED Fan 1 Bad/ Suction LED Fan 2 Bad/ Suction LED Fan 3 Bad
The suction fan 1 (fan 2/ fan 3) at the LED engine is disconnected from its control PCB or is faulty and has to
be replaced.
Exhaust LED Fan 1 Bad/ Exhaust LED Fan 2 Bad/ Exhaust LED Fan 3 Bad
The exhaust fan 1 (fan 2, fan 3) at the LED engine is is disconnected from its control PCB or is faulty and
should be replaced.
Iris Fan 1 Bad/ Iris Fan 2 Bad
The iris fan 1 (fan 2) which cools the iris and framing shutters in the fixture head is disconnected from its control
PCB or is faulty and should be replaced. A light output from the fixture is closed.
Arm Fan Bad
The fan which cools the PCB in the fixture head is disconnected from its control PCB or is faulty and should be
replaced. A light output from the fixture is closed.
Gobo Fan Bad
The fan which cools the gobo wheels in the fixture head is disconnected from its control PCB or is faulty and
should be replaced. A light output from the fixture is closed.