![Robe Robin BMFL FollowSpot User Manual Download Page 6](http://html.mh-extra.com/html/robe/robin-bmfl-followspot/robin-bmfl-followspot_user-manual_1468971006.webp)
6
4. Installation
Fixtures must be installed by a Qualified electrician in accordance with all
national and local electrical and construction codes and regulatio
ns.
4.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin BMFL FollowSpot is equipped with auto-switching power supply that automatically adjusts to any
50-60Hz AC power source from 200-240 Volts. The fixture is protected by one 12 A blow primary fuse.
If you install a cord cap on the power cable to allow connection to power outlets, install a grounding-type (earthed)
plug, following the plug manufacturer’s instructions.
To apply power, first check that the head pan and tilt locks are released.
The cores in the power cable are coloured according to the following table.
Core (EU)
Core (US)
Connection Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green Green
Earth
The earth has to be connected!
If you have any doubts about proper installation, consult a qualified electrician.
Attention: The powerCON is a connector without breaking capacity,
i.e. the powerCON should not be connected or disconnected under load or live!
Do not connect the fixture to a dimmer system!