7.7 Icon "Lamp menu"
Lamp Status
- The item enables to switch the lamp on/off.
The Osram Lok-it! HTI 1700/PS lamp is a cold
restrike type, that means, that it has to be cold before striking.
Settings
- The menu offers many items for setting of lamp behaviour.
Lamp Power
- The menu offers two levels of the lamp power: 1700W, 1500W and the option Quiet,
at which the lamp power is auto-controlled to ensure minimum noise of the fixture fans.
All these options are available at DMX channel 6. The factory setting is 1700W.
Lamp Ignition Delay
- The item allows to set the time delay( 0-90sec.) before igniting the lamp by DMX
command. If the lamp is started directly from the control panel, the set time delay will be ignored.
Lamp Light Sensor
- Select this item to switch the light sensor off. The option "On” is intended for a standard
operation.
The option "Off” is for “emergency operation” only! If the lamp light sensor is switched off, the fixture
will still try to ignite the lamp (even when the lamp is damaged or absent), on this account some electronics
parts of the fixture can be damaged!
Lamp On/Off Settings
- Use the menu to set rules for automatic switching on/off the lamp.
Lamp On Power On
- If the item is on, the lamp will be automatically turn on after switching the
fixture on.
Lamp Off via DMX
- The item enables to switch the lamp off via DMX command from DMX
controller.
Lamp On if DMX Present
- The item allows you to strike the lamp automatically after 26 seconds
if DMX signal is present on the fixture´s DMX input.
Lamp Off if not DMX
- The item allows you to switch off the lamp automatically after 2 minutes
if DMX signal is missing on the fixture´s DMX input.
8. RDM
This fixture supports RDM operation. RDM (Remote Device Management) is a bi-directional communications
protocol for use in DMX512 control systems, it is the new open standard for
DMX512 device configuration and
status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting
existing non-RDM equipment. By using a special „Start Code,“ and by complying with the timing specifications
for DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive
messages from specific moving lights.
RDM allows explicit commands to be sent to a device and responses to be received from it.
The list of commands for Robin BMFL FollowSpot is the following.
Parameter ID
Discovery command SET command
GET command
DISC_UNIQUE_BRANCH
*
DISC_MUTE
*
DISC_UN_MUTE
*
DEVICE_INFO
*
SUPPORTED_PARAMETERS
*
SOFTWARE_VERSION_LABEL
*
DMX_START_ADDRESS
*
*
IDENTIFY_DEVICE
*
*
DEVICE_MODEL_DESCRIPTION
*
MANUFACTURER_LABEL
*
DEVICE_LABEL
*
*
SENSOR_DEFINITION
*
SENSOR_VALUE
*
DISPLAY_INVERT
*
*
DISPLAY_LEVEL
*
*
PAN_INVERT
*
*
Summary of Contents for Robin BMFL FollowSpot
Page 1: ...1 Version 1 5 ...
Page 40: ...40 Photometric diagrams Min zoom ...