6
4. Installation
Fixtures must be installed by a Qualified electrician in accordance with all
national and local electrical and construction codes and regulatio
n.
4.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin 600E Wash is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz
AC power source from 00-40 Volts.
For use with 100-120 V supplies, both main 5 A fuses has to be exchanged for 15 A fuses which are
enclosed in the packing.
To install the 15 A fuses:
1. Disconnect the fixture from AC power.
2. Unscrew the "live" fuse holder on the rear panel of the base with a flat-tip screwdriver from the housing
(anticlockwise).
3. Remove the 8 A fuse from the fuse holder.
4. Put the 5 A fuse in the fuse holder.
5. Replace the fuse holder in the housing and screw it fully clockwise.
6. Repeat steps -5 for the "neutral" fuse holder
Install a suitable plug on the power cord, note that the cores in the power cord are coloured according to the
following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Core (US)
Connection Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green Green
Earth
4.2 Installing the lamp
DANGER ! Install the lamp with the device switched off only.
Unplug from mains before !
To insert the new lamp.
1. Disconnect the fixture from power and allow it to cool
at least 5 minutes.
2. Make sure that the fixture´s head is in the position as
shown on the picture (notices on the lamp cover are in
readable position) .Loosen the two quarter-turn
fasteners (1) marked “X,Y“ on the lamp cover to
open this cover.
3. Holding the lamp by its ceramic base, carefully
turn the lamp
to the left to loosen the lamp from
the lamp holder.
Gently pull the lamp out of the lamp holder
4. Holding the new lamp by its ceramics base, gently
insert the lamp to the lamp socket and turn the base
to the right. Make sure that the lamp is installed tightly
into the lamp socket.
Do not install a lamp with a higher wattage! A lamp
like this generates temperatures the device is not de-
signed for. Damages caused by non-observance are