background image

Eminere  

 

11 

Protection factor 

 

• CE: IP 67 

 

• US: Suitable for wet location  

 

Impact rating 

 

• CE: IK06 

 

Operating ambient temperature range 

 

• -20°C /+40°C (-4°F /+104°F) 

 

 

Operating temperature 

 

• +67°C 

@ A40°C

 (+153°F 

@ A104°F

 

 

Connection 

 

• Input: 

panel connector Amphenol ABAB-DMQ06000021-IN 

 

(P/N13052952)

  

• Output: panel connector Amphenol  ABAB-DAQ06000021 (P/N13052953) + water-tight cap 

 

Included items 

 

• 1 x Eminere 

 

• 1 x User manual  

 

Optional accessories 

 

 

Leader cables 
P/N 

Name 

13053005  Cable CE Leader FF 2m ABB1-DFQ06 
13053006  Cable CE Leader FF 5m ABB1-DFQ06         
13053007  Cable CE Leader FF 10m ABB1-DFQ06          
13053008  Cable CE Leader FF 25m ABB1-DFQ06      
13053009  Cable CE Leader FF 50m ABB1-DFQ06           
13053010  Cable US Leader FF 2m ABB1-DFQ06         
13053011  Cable US Leader FF 5m ABB1-DFQ06   
13053012  Cable US Leader FF 10m ABB1-DFQ06    
13053013  Cable US Leader FF 25m ABB1-DFQ06          
13053014  Cable US Leader FF 50m ABB1-DFQ06             
13053015  Cable CE Leader MM 2m ABB1-DMQ06     
13053016  Cable CE Leader MM 5m ABB1-DMQ06      
13053017  Cable CE Leader MM 10m ABB1-DMQ06     
13053018  Cable CE Leader MM 25m ABB1-DMQ06          
13053019  Cable CE Leader MM 50m ABB1-DMQ06    
13053020  Cable US Leader MM 2m ABB1-DMQ06         
13053021  Cable US Leader MM 5m ABB1-DMQ06        
13053022  Cable US Leader MM 10m ABB1-DMQ06     
13053023  Cable US Leader MM 25m ABB1-DMQ06      
13053024  Cable US Leader MM 50m ABB1-DMQ06   
13053025  Cable CE Leader FM 2m ABB1-DBQ06      
13053026  Cable CE Leader FM 5m ABB1-DBQ06          
13053027  Cable CE Leader FM 10m ABB1-DBQ06       

Summary of Contents for Eminere 1

Page 1: ...Version 1 1 ...

Page 2: ...s 1 Safety instructions 3 2 Fixture exterior view 4 3 Installation 5 3 1 Mounting the fixture 5 3 2 Connection to mains 5 4 Technical specifications 8 5 Cleaning and maintenance 13 5 1 Disposing of the product 13 6 ChangeLog 13 ...

Page 3: ...ing Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure the power cord is never crimped or damaged by sharp edges Check the fixture and the power cord from time to time Do not install the unit near an open flame During operation the housing becomes hot Refer servicing to qualified service personnel This fixture falls under protection class I Ther...

Page 4: ...xture only after having familiarized yourself with its functions Do not permit operation by persons not qualified to operate the fixture Most damages are the result of unprofessional operation Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons Please use the original packaging if the fixture is to be transported If this device will be operated in any...

Page 5: ...n in accordance with all national and local electrical and construction codes and regulations This device falls under class one and must be grounded The Eminere is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 277 Volts Wiring of input output connectors Input panel connector Output panel connector rear view from side of soldering rear ...

Page 6: ...t connect disconnect Emineres to the E box and each other when they are under voltage When you change any setting of the E box disconnect the E box from power and connect it to power again to activate changes which you have made Examples of connection for various versions of the E box Please read the E box user manual for more information about its setting and connection to Eminere modules Needed ...

Page 7: ...Eminere 7 E box Pro E box Lite ...

Page 8: ...RGBW RGBA single colour Beam angles assymetric wallwasher 9 15 30 50 65 100 10 x30 10 x60 35 x70 15 x90 Projected LED Life 120 000 Hrs L70 25 C Compatible drivers E box Daisy 1 single output 1 Main power Input Control DMX Art Net sACN W DMX control RDM Pixel control 1px 1ft 100 277V Input Connection via screw terminal inlets via grommet IP67 E box Star 6 outputs 1 Main power Input Control DMX Art ...

Page 9: ...1200mm 4ft Housing Aluminium extruded body with die casted end caps Tempered glass Cooling system Convection Total heat dissipation Eminere 1 85 BTU h calculated Eminere 2 171 BTU h calculated Eminere 3 256 BTU h calculated Eminere 4 307 BTU h calculated Weight 2 5 kg 5 5 lbs 4 2 kg 9 3 lbs 5 9 kg 13 lbs 8 7 kg 19 1 lbs Dimensions All dimensions in mm inch Eminere 1 ...

Page 10: ...Eminere 10 Eminere 2 Eminere 3 Eminere 4 ...

Page 11: ...06 13053009 Cable CE Leader FF 50m ABB1 DFQ06 13053010 Cable US Leader FF 2m ABB1 DFQ06 13053011 Cable US Leader FF 5m ABB1 DFQ06 13053012 Cable US Leader FF 10m ABB1 DFQ06 13053013 Cable US Leader FF 25m ABB1 DFQ06 13053014 Cable US Leader FF 50m ABB1 DFQ06 13053015 Cable CE Leader MM 2m ABB1 DMQ06 13053016 Cable CE Leader MM 5m ABB1 DMQ06 13053017 Cable CE Leader MM 10m ABB1 DMQ06 13053018 Cable...

Page 12: ...mper FF FM 2m ABC1 DFQ06 13053049 Cable CE Jumper FF FM 3m ABC1 FQ06 13053050 Cable CE Jumper FF FM 5m ABC1 DFQ06 13053051 Cable CE Jumper FF FM 10m ABC1 DFQ06 13053052 Cable US Jumper FF FM 0 25m ABC1 DFQ06 13053053 Cable US Jumper FF FM 0 5m ABC1 DFQ06 13053054 Cable US Jumper FF FM 1m ABC1 DFQ06 13053055 Cable US Jumper FF FM 2m ABC1 DFQ06 13053056 Cable US Jumper FF FM 3m ABC1 DFQ06 13053057 C...

Page 13: ...ease use ROBE OEM parts 5 1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes 6 ChangeLog This section summarizes changes in the user manual Version of the manual Date of issue Description of changes 1 1 07 10 2019 Inrush current added to chapter Technical Specifications Specifications are...

Reviews: