background image

3

1. Introduction 

The SubDrive 4 serves for power and control up to four ArcSource Submersible II LED modules. 

2. Safety information

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY

BEFORE POWERING OR INSTALLING YOUR SUBDRIVE 4 !

Save it for future reference.

DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!

The fixture was designed for outdoor use and it is intended for professional application only. It is not for house

-

hold use.

Make sure that the available voltage is not higher than stated on the fixture.

Be careful when removing fixture cover in order to get access to the control display and the fixture is under 

voltage. If you do not need to set the fixture, always disconnect the fixture from AC power before removing its 

cover.

Do not install the fixture near an open flame.

Refer servicing to qualified service personnel.

This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet 

with a protective  earthing connection.

Do not connect this fixture to a dimmer pack.

Keep combustible materials at least 10 cm away from the fixture.

Do not cover the fixture with cloth or other materials.

When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.

Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.

Operate the fixture only after having familiarized with its functions. Do not permit operation by persons not 

qualified for operating the fixture. 

Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!

Please use the original packaging if the fixture is to be transported.

If this device will be operated in any way different to the one described in this manual, the product may suf

-

fer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like 

short-circuit, burns, electric shock etc.

Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to 

the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, 

audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity.

The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given 

by this standard (e.g. transmitters in surrounding area) before installing the equipment.

The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m. 

Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia 

equipment – Emission Requirements according to class B.

Summary of Contents for ANOLIS Subdrive 4

Page 1: ...1 Version 1 4 ...

Page 2: ...ure exterior view 4 4 Mounting 5 5 SubDrive 4 menu 8 5 1 Fixture Address A001 8 5 2 Fixture information InFo 8 5 3 Personality PErS 9 5 4 Manual mode Man C 10 5 5 Test sequences tESt 10 5 6 Stand alone setting St AL 10 5 7 Special functions SPEC 11 6 Technical specifications 14 ...

Page 3: ...t exposed to extreme heat or dust Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons Please...

Page 4: ...4 3 Fixture exterior view 1 Top cover 6 DMX In 2 Fastening screws 7 DMX Out 3 Antenna cover 8 LED Output 1 4 Gore valve 9 LED Output 2 5 Power In 10 LED Output 3 11 LED Output 4 ...

Page 5: ...mm and two cable glands M12x1 5 serve for cables of diameter of 3 7mm We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of each cable gland before inserting it into the body of the gland Note enclosed reducing seal P N 13051388 serves for cable of diameter of 4 8mm Original seal has to be removed from the cable gland before installing the reducing seal This de...

Page 6: ...Source Submersible II connection DATA 24V red wire Communication orange wire Ground blue wire 6 Connect the fixture to mains 7 Set desired parameters in the fixture menu DMX address operating mode etc by means of display and four control buttons 8 Screw the top cover of the fixture back Check that all screws are firmly tightened ...

Page 7: ...7 RB 3091 ...

Page 8: ... number of operation hours P O t b the item shows total number of operation hours of the SubDrive 4 since the SubDrive 4 has been fabricated P O t 1 the item shows a total number of operation hours of the ArcSource Submersible II connected to the LED output 1 since this ArcSource Submersible II has been fabricated P O t 2 the item shows a total number of operation hours of the ArcSource Submersibl...

Page 9: ...es VEr d version of the SubDrive 4 VE L 1 version of the ArcSource Submersible II connected to the LED output 1 VE L 2 version of the ArcSource Submersible II connected to the LED output 2 VE L 3 version of the ArcSource Submersible II connected to the LED output 3 VE L 4 version of the ArcSource Submersible II connected to the LED output 4 VE V i version of the wireless DMX module if is installed...

Page 10: ...our temperature correction V C Vh a virtual colour wheel Stro a strobe shutter dim a dimmer din F a fine dimmer 4 Press the ENTER button and use the UP DOWN buttons to set value press the ENTER button to confirm it 5 5 Test sequences tESt Use this menu to run test sequences without an external controller which will show you some possibilities of using the ArcSource Submersible II 5 6 Stand alone s...

Page 11: ... output 4 CtO a colour temperature correction for all outputs V C Vh a virtual colour wheel for all outputs Stro a strobe shutter for all outputs dinn a dimmer for all outputs din F a fine dimmer for all outputs F tiM a fade time 0 25 5 seconds S tiM step time value 0 25 5 seconds CoPy this item duplicates the current prog step to the next prog step The item P End is increased automatically if you...

Page 12: ...Robe Universal Interface via a DMX cable 4 Switch the fixture to the update mode tab SPEC uPd b yES Note If you do not want to continue in the software update you have to switch off and on the fixture to escape from the updating mode We recommend to cancel all running programs on your computer before starting the software update 5 Double click the software uploader file e g DSU_SubDrive_4 exe in t...

Page 13: ... fixture stays in Updating mode and you will have to repeat the software update again Another way how to update software in the fixtures especially large installation of fixtures is to use the ROBE Uploader It is a software for automatized software update of Robe fixtures It takes advantage of RDM support For more information please see https www robe cz robe uploader ...

Page 14: ... SC 3 1 3 4 channels Editable Programs 3 up to 42 steps each Settings Addressing Via RDM communicator or Robe Universal Interface RUNIT PHYSICAL Weight 7 5 kg 16 53 lbs Number of LED Output zones 4 Max Load Per Zone 1x ArcSource Submersible II Total Load 4x ArcSource Submersible II Max Cable Length 100m Minimum mode 50m Medium mode 25m Maximum mode LED Output Connection Terminal Block DMX Connecti...

Page 15: ...mm inch September 10 2021 Copyright 2021 Robe Lighting All rights reserved All Specifications subject to change without notice Made in CZECH REPUBLIC by ROBE LIGHTING s r o Palackeho 416 20 CZ 75701 Valasske Mezirici ...

Page 16: ...t proportional Blue zone 2 0 255 Blue LEDs saturation control 0 100 255 default proportional White Amber zone 2 0 255 LEDs saturation control 0 100 255 default proportional Red zone 3 0 255 Red LEDs saturation control 0 100 255 default proportional Green zone 3 0 255 Green LEDs saturation control 0 100 255 default proportional Blue zone 3 0 255 Blue LEDs saturation control 0 100 255 default propor...

Page 17: ... Red full Green 0 Blue 0 White 0 step 176 214 Red full Green 0 Blue up White 0 proportional 215 Magenta Red full Green 0 Blue full White 0 step 216 246 Red down Green 0 Blue full White 0 proportional 247 Blue Red 0 Green 0 Blue full White 0 step 248 251 Rainbow effect with fade time from min max speed proportional 252 255 Rainbow effect without fade time from min max speed proportional Shutter Str...

Page 18: ...l Cool white zone 3 0 255 Cool white LEDs saturation control 0 100 255 default proportional Warm white zone 4 0 255 Warm white LEDs saturation control 0 100 255 default proportional Cool white zone 4 0 255 Cool white LEDs saturation control 0 100 255 default proportional Virtual Colour Wheel all zones 0 No function 0 default step 1 2 White 2800K step 3 4 White 3200K step 5 6 White 3800K step 7 8 W...

Page 19: ...andom strobe effect from slow fast proportional 224 255 Shutter open step Dimmer coarse all zones 0 255 Dimmer intensity from 0 to 100 0 default proportional Dimmer fine all zones 0 255 Dimmer intensity from min max 0 default proportional Copyright 2021 Robe Lighting s r o All rights reserved All Specifications subject to change without notice 6 2 5 2 ...

Page 20: ...ffect from slow fast proportional 96 127 Shutter open step 128 143 Opening pulses in sequences from slow fast proportional 144 159 Closing pulses in sequences from fast slow proportional 160 191 Shutter open step 192 223 Random strobe effect from slow fast proportional 224 255 Shutter open step Dimmer coarse all zones 0 255 Dimmer intensity from 0 to 100 0 default proportional Dimmer fine all zone...

Reviews: