background image

4

RND 305-00018

ENGLISH

Plug in the charger to AC mains (100 - 240V) wall socket.
The indicatiors light up one by one as charger goes through a series of self checks. Then all lights are on 

together and off  to indicate the end of checks except the operation “Standby” indicator.

Connect the red output lead to the positive terminal of the batt ery and the black lead to the negative 

teminal.

The “Standby” blinks to indicate that charger is ready for selection of Charge Mode.

User has 2 minutes to select the desired Charge Mode, and the charger will automatically enters into the 
last selected Charge Mode at the end of 2 minutes.

Select the appropiate Charge Mode by pressing the Mode butt on one or more times within 2 minutes. The 

Charge Mode indicator changes with each press “Sealed”          “Wet”           “Calcium-Calcium”          “Sealed” in 

cycle.

The Mode butt on will also be locked in 10 seconds aft er selection of Charge Mode.

If no pressing on the Mode key has been done aft er 2 minutes, the charger will automatically enters into 

the last selected charging mode.

DisplayI

ndications

Standby Mode 

฀  

Steady light on :

AC mains connected but charger is not yet connected to battery.

Blinking light on :

Battery is connected, 2 minutes to select charge mode before charger enters to last 
selected Charge Mode.

Check   Mode 

฀  

Steady light on :

For a few seconds initially for normal battery, charger checking battery.

Steady light on :

For longer time, charger in *desulphate charging.

Blinking light on :

When connected to battery showing the battery is not suitable for charge.

Blinking light on :

After unit in Charging Mode for long time (max. 40 hrs.), or desuphating charge 
(max.8 hrs.), battery still cannot hold charge or cannotb e desuphated. Remove 
battery.

Charging Mode 

฀  

Steady light on :

Charging in progress (desulphate and bulk or absorption charge stage)

Float / Maintenance Charge Mode 

฀  

Steady light on :

Battery is fully charged and Charger in Float / Maintenance Pulse Mode 

Alarm 

฀  

The blinking alarm indicates charging fault, check following faults.
Output connectors short circuit
Output connectors in wrong polarity
Over temperature Protection activated, charging has stopped.

2

6

7

8

9

Display

Indication

Summary of Contents for 305-00018

Page 1: ...1 RND 305 00018 USER MANUAL BEDIENUNGSANLEITUNG Smart Charger RND 305 00018...

Page 2: ...sulphate Pulse Charging B Constant current pulse Bulk charge C PWM Absorption charge D PWM Float Maintenance charge 2 Wet sealed lead GEL AGM acid and Calcium Calcium battery type selection 3 Select a...

Page 3: ...leave charger connected for a long period of time As all batteries fail eventually A battery that fails during charging is usually taken care of by the charger s protection controls However accident c...

Page 4: ...automatically enters into the last selected charging mode DisplayI ndications Standby Mode Steady light on AC mains connected but charger is not yet connected to battery Blinking light on Battery is...

Page 5: ...y A In the case the Check Mode indication is lit longer the charger is in desulphate charging After some time if desulphation of the battery is successful the charger will switch to normal charging an...

Page 6: ...age Cal Cal battery Mode 29 6 V Construction IP 45 splash proof Poly carbonate casing Accessories Detachable leads with crocodile clips and leads with ring terminals Protection Overload Short Circuit...

Page 7: ...7 RND 305 00018 USER MANUAL BEDIENUNGSANLEITUNG Smart Charger RND 305 00018...

Page 8: ...fen und Quali zieren der zu desulfatierenden Batterie beim Impulsladen B Konstantstrom Impulsvolllastladung C PWM Absorptionsladung D PWM Erhaltungs Wartungsladung 2 Auswahl von Nass verschlossenem G...

Page 9: ...ger t ber einen langen Zeitraum hinweg angeschlossen bleiben soll pr fen Sie nach dass es den Erhaltungsmodus erreicht hat Alle Batterien fallen irgendwann aus Der Ausfall einer Batterie w hrend des L...

Page 10: ...ulfatierung max 8 Std kann die Batterie immer noch keine Ladung halten oder desulfatiert werden Entfernen Sie die Batterie Schliessen Sie das Ladeger t an eine Netzsteckdose 100 240 V an Die Anzeigen...

Page 11: ...ngsladen kann nur eine geringf gig sulfatierte Batterie aufbereitet werden A Wenn die Pr fmodusanzeige l ngere Zeit leuchtet arbeitet das Ladeger t in Desulfatierungs Ladebetrieb Wenn die Desulfatieru...

Page 12: ...annung Cal Cal Batteriemodus 29 6 V Ausf hrung IP 45 spritzwassergesch tzt Polycarbonatgeh use Zubeh r Abnehmbare Kabel mit Krokodilklemmen und Kabel mit Ringkabelschuhen Schutz berladung Kurzschluss...