Rhein - Nadel Automation GmbH 

                     7 

                                                         14.04.2014 

VT-BA Typ ESG 1000 GB 

 

4.  

Plan showing the position of the operating elements on the boards 

 
 

Netzkabel

Externer Kontakt

Externe Spannung
24 V, DC

3

1

3

2

3

3

3

4

1

2

3

4

5

6

7

8

9

Netzschalter

X1

10kOhm

X16

Erdung
Gehäuse

LP 1334

Ausgangsstec kdose

S1

1 2

3 4

PE

X8 X18

ESG 1000

Potentiometer

Pos. 52

Pos. 59

Pos. 50 +  51

Detail B

Pos. 80

Freigabe

 
 

Release by voltage signal 

The connection is done on the fasteners 31 (GND) and 32 (+24 VDC). The drive starts, when a signal is fed between 
10 and 30 volt direct current in correct polarity. The input is protected against faulty polarity. The use of an optocoupler 
in the control unit makes the input potential-free and allows the installation with unscreened cables of nearly any length. 
Here too high-energy interferences should be avoided

.

 

 

Token 

Commentasy 

S0 

Switch 
110 V 

– 230 V 

Electric voltage 

S1 

External release 

 

      

 

 

When replacing the fuse the preset value of M 6,3 A is to be used in any case. A fuse which is rated 
too high can lead to breakage of the conrol unit.

 

Release 
External contact 
 
External voltage 
24 V. DC 

Electric cable Pos. 80 

Electric switch Pos. 
52 

Casing ground 
Detail B 

Exit xocket 
Pos. 50 + 51 

Summary of Contents for ESG 1000

Page 1: ...Rhein Nadel Automation GmbH 1 19 09 2012 VT BA Typ ESG 1000 GB Operating instructions Control units for oscillating drives ESG 1000 BA Rhein Nadel Automation GmbH...

Page 2: ...he boards 7 5 Dimensional drawing 8 6 Connection diagram 8 Declaration of conformity as defined by Low voltage directive 2014 35 EU and EMC directive 2014 30 EU Herewith we declare that the product co...

Page 3: ...approx 0 5 seconds If necessary this time can be changed in the device 1 2 EC Conformity The control device corresponds to the following regulations Low voltage directive 2014 35 EU EMC directive 2014...

Page 4: ...ade and the control unit is switched on the following points must in any case be checked Is the control unit closed properly and with all screws Are the existing plug fixing devices locked into place...

Page 5: ...ion 3 to 4 switches the control unit into operating mode 2 100 or 120 Hz If this connection is missing the control unit operates in the operating mode 1 50 or 60 Hz As a standard oscillating transport...

Page 6: ...witched on Should it be preferred that the control unit work in start stop operation then the control unit should be opened observing all of the precautionary measures listed above and the jumper S1 r...

Page 7: ...ignal is fed between 10 and 30 volt direct current in correct polarity The input is protected against faulty polarity The use of an optocoupler in the control unit makes the input potential free and a...

Page 8: ...Rhein Nadel Automation GmbH 8 14 04 2014 VT BA Typ ESG 1000 GB 5 Scale Drawing 6 Connecting Diagram...

Page 9: ...lding rna de PSA Zuf hrtechnik GmbH Dr Jakob Berlinger Weg 1 D 74523 Schw bisch Hall Tel 49 0 791 9460098 0 Fax 49 0 791 9460098 29 Email info psa zt de HSH Handling Systems AG Wangenstr 96 CH 3360 He...

Reviews: