Technical data
1.1 Functional description
The compact design of the control unit can supply all RNA-control units up to a load current of 6 ampere. It is intended
for individual installation directly at the oscillating drive and completely pluggable. The correcting range for the potenti-
ometer in the front plate has been adjusted in the factory at a reference drive and allows the adjustment of the output
voltage from 40 to 280 volt
eff .
The illuminated rocking switch in the front plate separates the control unit with 2 poles from the mains. For frequent
switching or operation with a superordinated control unit there is the possibility of wattless disconnection by means a
potential-free contact as well as by 16-30VDC voltage signal. The intervention into the device necessary for that is de-
scribed under point 3.5,
Release of the function by external components
.
The soft start, a time-controlled bringing-up of power to the adjusted value after switching on, is fixed with approx. 0.5
seconds. If necessary this time can be changed in the device
.
1.2
EC - Conformity
The control device corresponds to the following regulations:
Low voltage directive 2014/35/EU
EMC directive 2014/30/EU
Applied harmonized standards:
DIN EN 60204 T1
EN 61439-1
The control device corresponds also to the UL/CSA regulations.
1.3
Technical data
Mains connection: 230 Volt AC, 50/60 Hz, +10 -15% or
115 Volt AC, 50/60 Hz, +10 -15% , internally selectable
Output voltage: 40...208 Volt (eff.) adjustable, (230 V mains)
20...105 Volt (eff.) adjustable, (115 V mains)
Load current: max. 6 Amp.(eff)
Safety fuse: Fine-wire fuse 5 x 20; 6,3 MT time-lag
Operating modes: 1. symmetric full wave operation
(oscillating frequency = double mains frequency)
2. asymmetric half wave operation
(oscillating frequency = mains frequency
Operating mode selection: Encoding bridge in the load plug
Function release: selectable by internal jumpers
Release by external contact:: potential-free make contact, load approx. 6 mA
Release by external signal: Reverse battery protected input, level 16...30 VDC
at 24 Volt approx. 8 mA
Soft start: internally adjustable, standard approx.. 0,5 sec.
Insulation type: IP 54
Radio interference suppression: according to EMV - regulations
Dimensions: 104 x 213 x 153 (width x height x depth)