RMS Technologies
Page 35
Version 1.20
R101 Single Axis Driver/Indexer Manual
May 31, 2005
SV
Start Velocity<value>
Command or Query 250 to 15,000
Reads or sets the velocity used for the first step in a position move. Value based on
motor performance.
Command Example
#ASV500<cr><lf> Sets Start Velocity to 500 PPS.
Default value is 1,000