RMS Technologies
Page 23
Version 1.20
R101 Single Axis Driver/Indexer Manual
May 31, 2005
MA
My Address<value>
Command or Query 65 to 90.
Reads or sets the unit address. The value read or entered is the decimal value of the
ASCII character designated as the unit address. (65 = ‘A’ and 90 = ‘Z’)
The change to a new address is immediate, in that the command response will use
the new address
Command Example
#AMA88<cr><lf> Sets the unit address to 88 (‘X’).
Default value is 65
Address
Value
A
65
B
66
C
67
D
68
E
69
F
70
G
71
H
72
I
73
J
74
K
75
L
76
M
77
N
78
O
79
P
80
Q
81
R
82
S
83
T
84
U
85
V
86
W
87
X
88
Y
89
Z
90