1.4.2.4.
Installation
Note
Installations disturbing the gas flow directly upstream of the turbine meter
must be avoided
(see DVGW guideline G 492 II and PTGB guideline G 13).
An inlet pipe of at least 2 x DN is required upstream from the turbine meter TME400.
The inlet pipe must be designed as a straight pipe section with the same nominal di-
ameter as the meter. With heavy upstream pertubations, installation of straighteners
is recommended (refer to the table on the next page). A pipe or bend with the nomi-
nal diameter of the meter having a total length of 2 x DN must be arranged down-
stream from the meter.
Temperature measuring devices must be installed at a distance of at least 1 x DN or
at least 300 mm with nominal diameters
DN 300.
If there is pertubation (e.g. a gas pressure control device) upstream from the inlet
pipe, a perforated plate straightener is also necessary. Perforated plate straighteners
according to ISO 5167-1 or the type RMG LP-35, which cause a pressure loss by a
factor of 2.5 in comparison with the standard straightener, can be used.
Recommended installation with straightener
Perforated plate straightener LP 35
1
Perforated plate straightener
•
The opening angle of the reducing or expansion pieces which are installed up-
stream from the TME400 turbine meter must not be more than 30°.
Note
If necessary, a screen must be installed before the inlet pipe of the meter for
protection of the turbine meter from foreign objects which may be present in
the gas flow. The screen can be, for example, a perforated plate/filter of
0.15 mm.
Summary of Contents for TME400
Page 1: ...Operating Manual Turbine Meter TME400 VC VCF Issued July 01st 2021 Version 08 Firmware 1 06 ...
Page 50: ...2 Installation MANUAL TME400 VCF EN08 July 01st 2021 44 Ex version ...
Page 51: ...2 Installation MANUAL TME400 VCF EN08 July 01st 2021 45 Ex version with current module ...
Page 52: ...2 Installation MANUAL TME400 VCF EN08 July 01st 2021 46 Non Ex version ...
Page 130: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 124 ...
Page 131: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 125 ...
Page 132: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 126 ...
Page 133: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 127 ...
Page 134: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 128 ...
Page 135: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 129 ...
Page 136: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 130 ...
Page 137: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 131 ...
Page 138: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 132 ...
Page 139: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 133 ...
Page 140: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 134 ...
Page 141: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 135 ...
Page 142: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 136 ...
Page 143: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 137 ...
Page 144: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 138 ...
Page 145: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 139 ...
Page 146: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 140 ...
Page 147: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 141 ...
Page 148: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 142 ...
Page 149: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 143 ...
Page 150: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 144 ...
Page 151: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 145 ...
Page 152: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 146 ...
Page 153: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 147 ...
Page 154: ...APPENDIX MANUAL TME400 VCF EN08 July 01st 2021 148 ...