OPERATION
...............................................................................................................................................................................................................
...............................................................................................................................................................................................................
Manual EC 24 · EN05 · 2015-02
19
Totalizer factor (decimal places)
You can set the totalizer factor in coordinate Z 01.
There are the following setting options:
Totalizer factor
Multiplier for value
displayed
Decimal places
0.01
2
0.1
1
1
0
10
10
0
100 100 0
Example:
If the factor has been set to 0.1, the meter reading will be displayed with one decimal.
If the factor has been set to 10, the value displayed will be shown without decimals and you will
obtain the actual meter reading by multiplying the value displayed by 10.
Output pulse value
The output pulse value indicates how many LF output pulses correspond to one cubic metre.
The output pulse value can be entered in coordinate A 05 from 0.01 to 100 as required.