28.14 Level Meter
The Digiface calculates all the display values Peak, Over and RMS in hardware, in order to be
capable of using them independent of the software in use, and to significantly reduce the CPU
load.
Tip:
This feature, the
Hardware Level Meter
, is used by
DIGICheck
(Windows only, see chap-
ter 16) to display Peak/RMS level meters off all channels, nearly without any CPU load.
The level meters integrated in TotalMix - considering their size - cannot be compared with
DIGICheck. Nevertheless they already include many useful functions.
Peak and RMS is displayed for every channel. 'Level Meter Setup' (menu Options or F2) and
direct keyboard entry (
hotkeys
) make various options available:
•
Display range 40 or 60 dB (
hotkey 4 or 6
)
•
Release time of the Peak display (Fast/Medium/Slow)
•
Numerical display selectable either Peak or RMS (
Hotkey E or R
)
•
Number of consecutive samples for Overload display (1 to 15)
•
RMS display absolute or relative to 0 dBFS (
Hotkey 3 or 0
)
The latter is a point often overlooked, but nonetheless
important. A RMS measurement shows 3 dB less for
sine signals. While this is mathematically correct, it is
not very reasonable for a level meter. Therefore the
RMS readout is usually corrected by 3 dB, so that a
full scale sine signal shows 0 dBFS on both Peak and
RMS meters. This setting also yields directly readable
signal-to-noise values. Otherwise the value shown
with noise is 3 dB better than it actually is (because
the reference is not 0 dB, but -3 dB). For example in
WaveLab.
The value displayed in the text field is independent of
the setting 40/60 dB, it represents the full 24 bit range
of the RMS measurement, thus making possible a
SNR measurement 'RMS unweighted', which you
would otherwise need extremely expensive meas-
urement devices for. An example: An
RME ADI-8 DS
connected to the Digiface's ADAT port will show
around -113 dBFS on all eight channel's input level
meters.
This level display will constantly bring the reduced dynamic range of your equipment, maybe of
the whole studio, in front of your eyes. Nice to have everything 24 bit - but still noise and hum
everywhere in the range around -90 dB or worse... sorry, but this is the disappointing reality.
The up-side about it is that TotalMix allows for constantly monitoring the signal quality without
effort. Thus it can be a valuable tool for sound optimization and error removal in the studio.
Measuring SNR (Signal to Noise) requires to press R (for RMS) and 0 (for referring to 0
dBFS, a full scale signal). The text display will then show the same value as an expensive
measurement system, when measuring ‘RMS unweighted’.
Note: There is no RMS calculation for the third row, the physical outputs. Therefore the green
bars show the peak value only.
Summary of Contents for Hammerfall Digiface
Page 5: ...User s Guide HDSP System Digiface RME 5 User s Guide Digiface General...
Page 42: ...42 User s Guide HDSP System Digiface RME...
Page 50: ...50 User s Guide HDSP System Digiface RME...
Page 70: ...70 User s Guide HDSP System Digiface RME User s Guide Digiface Technical Reference...
Page 78: ...78 User s Guide HDSP System Digiface RME 35 Block Diagram Digiface...