User's Guide HDSP System Multiface II
© RME
41
The word clock input of the Hammerfall DSP is a high-impedance type ensuring maximum flexi-
bility, and is therefore not terminated. If normal termination is necessary (e.g. because Ham-
merfall DSP is the last device in the chain), simply connect a T-adapter to its BNC input jack,
connect the cable supplying the word clock signal to one arm of the T-adapter and terminate the
other with a 75 Ohm resistor (as a short BNC plug).
In case Hammerfall DSP resides within a chain of devices receiving word clock, plug a T-
adapter into Hammerfall DSP’s BNC input jack and the cable supplying the word clock signal to
one end of the adapter (as above), but connect the free end to the next device in the chain via a
further BNC cable. The last device in the chain should be terminated using another T-adapter
and a terminator plug as described in the previous paragraph.
24.3 Operation
The green Lock LED on the front (STATE) will light up as soon as a word clock signal is de-
tected. To change to word clock as clock source, activate the
Clock Source Word
in the field
Clock Mode
within the Settings dialog. The status display
Current
changes to
Word
as soon as
a valid signal is present at the BNC jack. This message has the same meaning as the green
state LED, but appears on the monitor, i.e. the user can check immediately whether a valid
word clock signal is present and is currently being used.
The word clock output of the Multiface is constantly active, providing the current sample fre-
quency as word clock signal. As a result, in Master mode the provided word clock is defined by
the currently used software. In Slave mode the provided frequency is identical to the one pre-
sent at the currently chosen clock input. When the current clock signal fails, the Multiface
switches to Master mode and adjusts itself to the next, best matching frequency (44.1 kHz, 48
kHz etc.).
Selecting
Single Speed
in the Settings dialog (Output Format Word) causes the output signal to
always stay within the range of 32 kHz to 48 kHz. So at 96 kHz sample rate, the output word
clock is 48 kHz.
Summary of Contents for DSP Multiface
Page 5: ...User s Guide HDSP System Multiface II RME 5 User s Guide Multiface II General...
Page 42: ...42 User s Guide HDSP System Multiface II RME...
Page 43: ...User s Guide HDSP System Multiface II RME 43 User s Guide Multiface II TotalMix...
Page 45: ...User s Guide HDSP System Multiface II RME 45...
Page 67: ...User s Guide HDSP System Multiface II RME 67 User s Guide Multiface II Technical Reference...
Page 74: ...74 User s Guide HDSP System Multiface II RME 31 Diagrams 31 1 Block Diagram Multiface II...
Page 76: ...76 User s Guide HDSP System Multiface II RME...
Page 77: ...User s Guide HDSP System Multiface II RME 77 User s Guide Multiface II Miscellaneous...