10. Technical Specifications
10.1 Inputs
AES/EBU
•
4 x XLR, transformer balanced, ground-free, according to AES3-1992
•
High-sensitivity input stage (< 0.3 Vpp)
•
SPDIF compatible (IEC 60958)
•
Accepts Consumer and Professional format, copy protection will be ignored
•
Single Wire: 4 x 2 channels 24 bit, up to 192 kHz
•
Double Wire: 4 x 2 channels 24 bit 96 kHz, equalling 4 channels 192 kHz
•
Double Wire: 4 x 2 channels 24 bit 48 kHz, equalling 2 channels 192 kHz
•
Quad Wire: 4 x 2 channels 24 bit 48 kHz, equalling 2 channels 192 kHz
•
Lock range: 28 kHz - 104 kHz, 162 kHz - 204 kHz
•
Jitter when synced to input signal: < 1 ns
•
Jitter suppression: > 30 dB (2.4 kHz)
SPDIF (Front)
•
as AES/EBU, but connected via TOSLINK
•
Auto Input Detection: replaces AES input channels 1/2
ADAT Optical
•
2 x TOSLINK, according to Alesis specification
•
Standard: 8 channels 24 bit, up to 48 kHz
•
S/MUX: 2 x 8 channels 24 bit / 48 kHz, equalling 8 channels 24 bit 96 kHz
•
S/MUX4: 2 x 8 channels 24 bit / 48 kHz, equalling 4 channels 24 bit 192 kHz
•
Bitclock PLL ensures perfect synchronisation even in varispeed operation
•
Lock range: 28 kHz – 54 kHz
•
Jitter when synced to input signal: < 1 ns
•
Jitter suppression: > 30 dB (2.4 kHz)
TDIF
•
2 x D-sub 25 pin, according to TDIF-1
•
Standard: 8 channels 24 bit, up to 48 kHz
•
Double Wire: 2 x 8 channels 24 bit / 48 kHz, equalling 8 channels 24 bit 96 kHz
•
Quad Wire: 2 x 8 channels 24 bit / 48 kHz, equalling 4 channels 24 bit 192 kHz
•
Lock range: 30 kHz – 54 kHz
•
Jitter when synced to input signal: < 1 ns
•
Jitter suppression: > 30 dB (2.4 kHz)
Word Clock
•
BNC, not terminated (10 kOhm)
•
Switch for internal termination 75 Ohm
•
Automatic Double/Quad Speed detection and internal conversion to Single Speed
•
SteadyClock guarantees super low jitter synchronization even in varispeed operation
•
Transformer coupled, galvanically isolated input
•
Not affected by DC-offsets within the network
•
Signal Adaptation Circuit: signal refresh through auto-center and hysteresis
•
Overvoltage
protection
•
Level range: 1.0 Vpp – 5.6 Vpp
•
Lock range: 28 kHz – 220 kHz
•
Jitter when synced to input signal: < 1 ns
•
Jitter suppression: > 30 dB (2.4 kHz)
Summary of Contents for ADI-192 DD
Page 4: ...4 User s Guide ADI 192 DD RME...
Page 5: ...User s Guide ADI 192 DD RME 5 User s Guide ADI 192 DD General...
Page 12: ...12 User s Guide ADI 192 DD RME...
Page 13: ...User s Guide ADI 192 DD RME 13 User s Guide ADI 192 DD Usage and Operation...
Page 29: ...User s Guide ADI 192 DD RME 29 User s Guide ADI 192 DD Technical Reference...
Page 40: ...40 User s Guide ADI 192 DD RME 12 Block Diagram...