Remove the resin attached to the pressure sensing part (diaphragm
and its surrounding section) after melting it by applying light heat to
the side of the pressure sensing part using a burner (Do not let the
temperature exceed 400
C). In addition, care should be taken not
to scratch the pressure sensing block.
If not, diaphragm damage or resin leakage may result.
3.1.3 Cautions during extruder cooling down
If the temperature is decreased while resin remains in the
extruder
with the pressure sensor installed, the
diaphragm may be depressed
and deformed by resin
contraction, etc. As a result, a measurement
error or
pressure dead-band may occur. If the extruder is
cooled
down, completely remove all the resin remaining
in the barrel, or
remove the sensor.
Especially take care for the low pressure sensor,
as this effect becomes serious.
3.1.4 Dimensions
CZ-100P- HB
HC
Unit:
mm
Measurement range: 0 to 20 MPa, 0 to 35 MPa, 0 to 50 MPa, 0 to 70 MPa,
0 to 100 MPa
Mounting Hold Dimensions
42
17
21
L3
L2
L1
0
0.2
10
0.
1
0.
2
14
0
0.
2
L4
L
80
13 10
103
L
Standard Dimensions
Fixing screws of sensor finished
to JIS B grade.
Finish to allow loose fitting.
Connector receptacle
PRC03-23A10-7F
Hexagon flat
head bolt 23
Lead pipe cover
(SUS304)
PF3/8
(JIS B grade)
Tip pressure
receiving side:
Diaphragm
(SUS630)
Set screw
L1
L3
20
10
.3
0.
1
15
.2
0.
1
PF3/8
L3 L4
Weight
30
30
HB
HC
90
120
Approx. 650 g
Approx. 700 g
150
180
L
8
8
L1
4
4
L2
Install the sensor so that the
diaphragm surface does not
protrude from this surface.
L2
2
Mounting Hold
Dimensions
18
0.
1
0.
2
24
0.
1
0.
2
L2
20
80
13
133
L
42
17
17
PF3/4
(JIS B grade)
Tip pressure
receiving side:
Diaphragm
(SUS630)
Lead pipe cover
(SUS403)
Hexagon flat
head bolt 27
Flat head bolt 14
Connector receptacle
PRC03-23A10-7F
C type snap ring
CZ-100P-HL
Unit:
mm
Measurement range: 0 to 20 MPa, 0 to 35 MPa, 0 to 50 MPa,
0 to 70 MPa, 0 to 100 MPa
Measurement range: 0 to 5 MPa, 0 to 10 MPa
(Loose nut type)
CZ-100P-HL
(Low pressure loose nut type)
20
L3
120
L
L1
30
18
.3
0.
1
50
L2
2
24
.5
0.
1
PF3/4
Install the sensor so that the
diaphragm surface does not
protrude from this surface.
Fixing screws of sensor finished
to JIS B grade.
Finish to allow loose fitting.
Standard Dimensions
Weight
A
Approx. 0.9 kg
B
Approx. 1.0 kg
C Approx.
1.2
kg
146
195
L
250
20
20
L1
20
6
L2
110
45
L3
45
45
55
0
0.2
L1
L3
120
20
Unit:
mm
CZ-100P-LLA
Measurement range*: 0 to 0.5 MPa, 0 to 1 MPa
40
17
17
PF3/4
(JIS B grade)
Lead pipe cover
(SUS403)
Hexagon flat
head bolt 23
Connector receptacle
PRC03-23A10-7F
C type snap ring
Tip pressure
receiving side:
Diaphragm
(SUS630)
60
13
Flat head bolt
14
20
L1
0
0.2
6
113
L
Mounting Hold
Dimensions
L2
18
0.
1
0.
2
24
0.
1
0.
2
L
Standard Dimensions
Approx. 0.9 kg
Weight
A
146
L
20
L1
6
L2
45
L3
L1
30
18
.3
0.
1
50
L2
2
24
.5
0.
1
PF3/4
Install the sensor so that the
diaphragm surface does not
protrude from this surface.
Fixing screws of sensor finished
to JIS B grade.
Finish to allow loose fitting.
* Z-1024 or Z-1024A type: 0 to 1 MPa
Z-1024 or Z-1024A type:
24
0
0.2
3.1.5 Pressure sensor installation
1.
Make sure the mounting hole is correctly machined. If installing
the pressure sensor into a previously used hole, make sure the
hole is thoroughly cleaned to remove any plastic residue.
2.
Lubricate the threads with a high temperature anti-seize lubricant.
3.
Tighten the hexagon nut part with a torque wrench. When tightening
the pressure sensor, always tighten only the hexagon nut part.
Fixed nut type (PF3/8 thread: HB, HC type): 30.0 N
m
[300 kgf
cm]
Loose nut type (PF3/4 thread: LL, HL, LLA type): 60.0 N
m
[600 kgf
cm]
Fixed nut type (Unified thread: UB, UC type): 30.0 N
m
[300 kgf
cm]
Tighten the pressure sensor to secure it after the
temperature rises.
Do not tighten any block other than the hexagonal nuts,
since this may damage the pressure sensor.
3.2. Output Converter (PCT-300)
3.2.1 Mounting cautions
(1)
This instrument is intended to be used under the following
environmental conditions.
(IEC61010-1)
[OVERVOLTAGE CATEGORY II, POLLUTION DEGREE 2]
(2) Use this instrument within the following environment conditions:
Allowable ambient temperature:
0 to 50
C
(32 to 122
F)
Allowable ambient humidity:
45 to 85 %RH
Installation environment conditions: Indoor use,
Altitude up to 2000 m
(3) Avoid the following when selecting the mounting location:
Rapid changes in ambient temperature, which may cause
condensation.
Corrosive or inflammable gases.
Direct vibration or shock to the mainframe.
Water, oil, chemicals, vapor or steam splashes.
Excessive dust, salt or iron particles.
Excessive induction noise, static electricity, magnetic fields or
noise.
Direct air flow from an air conditioner.
Exposure to direct sunlight.
Excessive heat accumulation.
(4)
Mount this instrument in the panel considering the following
conditions:
Provide adequate ventilation space so that heat does not build up.
Do not mount this instrument directly above equipment that
generates large amount of heat (heaters, transformers,
semi-conductor functional devices, large-wattage resistors.)
If the ambient temperature rises above 50
C, cool this instrument
with a forced air fan, cooler, etc. Cooled air should not blow
directly on this instrument.
In order to improve safety and the immunity to withstand noise,
mount this instrument as far away as possible from high voltage
equipment, power lines, and rotating machinery.
High voltage equipment: Do not mount within the same panel.
Power lines:
Separate at least 200 mm.
Rotating machinery:
Separate as far as possible.
For correct functioning mount this instrument in a horizontal
position.
In case this instrument is connected to a supply by means of a
permanent connection, a switch or circuit-breaker shall be included
in the installation. This shall be in close proximity to the equipment
and within easy reach of the operator. It shall be marked as the
disconnecting device for the equipment.
3.2.2 Dimensions
30
92
0
0.8
25
45
0
0.6
43
パネルカット
(
単位
: mm)
96
48
12
100
91
(1
00)
To prevent electric shock or instrument failure, always
turn off the power before mounting or removing the
instrument.
WARNING
!
(Unit: mm)
Panel cutout
dimensions
LL