RJL Warranty information

RJL warrants its Bioelectrical Impedance Equipment against defects in materials and workmanship for a period
of twelve (12) months from the date of shipment if the Equipment is in the possession of the original user and
has been subject to normal operating conditions. RJL will, at its option, repair or replace FOB its factory in
Clinton Township, Michigan, any Equipment which, upon its examination, is determined to be defective in
workmanship or materials. RJL's determination shall be final. RJL assumes no responsibility for reimbursing
Customer for repair or replacement costs incurred without RJL's prior authorization. 

RJL warrants that its Software will conform to its Software description applicable at the time of order for a 
period of twelve months from the date of shipment, if the Software is in the possession of the original user and 
has been subject to normal operating conditions. RJL will, at its option, confirm or replace FOB its factory in 
Clinton Township, Michigan, the Software that, upon its examination, is determined to be defective. RJL's 
determination shall be final. In the event RJL shall give written notice to Customer of any updated or revised 
software material and Customer fails to forthwith use the same, RJL shall be released from any and all liability 
related to or resulting from Customer's disregard of such notice. 

THE WARRANTIES STATED HEREIN ARE EXCLUSIVE AND COMPRISE RJL'S SOLE AND ENTIRE 
WARRANTY OBLIGATIONS AND LIABILITITES IN CONNECTION WITH THE EQUIPMENT AND 
SOFTWARE SOLD AND LICENSED HEREUNDER, AND ARE IN LIEU OF AND EXCULDE ALL 
OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARISING BY OPERATION OF LAW OR 
OTHERWISE, INCLUDING, BUT NOT LIMTED TO, WARRANTIES OR MERCHANT ABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE. 

Limitation of liability

RJL SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, ECONOMIC OR 
CONSEQUENTIAL DAMAGES ARISING OUT OF ANY BREACH OR WARRANTY, EXPRESSED OR 
IMPLIED. CUSTOMER'S SOLE REMEDY FOR ANY SUCH BREACH OF WARRANTY SHALL BE THE
REPAIR OR REPLACEMENT OF THE EQUIPMENT OR SOFTWARE. 

How to make a warranty claim:

The customer should notify RJL of a warranty claim at (800) 528-4513. Please provide the model and serial 
numbers of the unit, date of purchase, warranty period, and description of the defect. If RJL requests, the 
Customer will, at its own expense, deliver the equipment in appropriately protective packing to RJL Systems. 
RJL Systems will pay for the return shipping expense

What is not covered:

Accessories are not covered under this warranty. Warranty  terms do not apply if repairs/replacement  are
needed   due   to   customer   using   the   device   improperly,   physical   damage   caused   by   neglect/abuse,   or   if
instrument is disassembled by the customer. 
For Analyzers not purchased directly

 

from RJL Systems, contact your service provider for further information. 

If the Analyzer is not working properly, please contact RJL Systems Service Department 
for assistance before

 

shipping the unit back for diagnostic evaluation. 

- 19 -

Summary of Contents for QUANTUM V SEGMENTAL BIA

Page 1: ...s introduces Segmental BIA QUANTUM V SEGMENTAL BIA Bioelectrical Impedance Analyzer USER S MANUAL RJL Systems 33939 Harper Avenue Clinton Township MI 48035 USA 800 528 4513 fax 586 790 0205 www rjlsys...

Page 2: ...ng protocol for the subject patient 11 Performing the segmental BIA test 12 ON OFF push buttons 12 Understanding the display screens 13 Proper care of the analyzer and cables 14 Subject cable informat...

Page 3: ...um V Segmental BIA System and accompanying software are marketed under the following FDA clearances K830292C K862383 and K070999 RJL Systems is registered as an ISO 13485 2016 compliant company RJL in...

Page 4: ...ubject cables with protective pouch Test resistor and capacitor network Four 4 Zip Lock Packs of electrodes 800 total electrodes 100 tests Quantum V Segmental BIA User s Manual and video thumb drive B...

Page 5: ...comparative percentage or change over time Health care professionals such as physicians who are interested in regional muscle wasting will find the Quantum V Segmental BIA a valuable tool In addition...

Page 6: ...records can be saved A segmental scan is started by pushing the ON button or by selecting a sampling time interval that can range from seconds to hours If the interval is more than 1 minute the instru...

Page 7: ...al BIA software product All regional body composition values including regional resistance and reactance values can be exported as a CSV file This file is read by most spread sheet programs including...

Page 8: ...is done with eight 8 electrodes attached to the right and left hand and foot as shown below when the subject is laying in a supine position The source and detecting electodes must follow the descripti...

Page 9: ...Subject connected with all eight leads lying in a supine position 9...

Page 10: ...o lead sets are pushed into the connector on the rear of the Quantum V Connect the USB cable to the USB PORT on the back of the Quantum V to a laptop computer with the Segmental BIA application instal...

Page 11: ...ive barrier The subject should not be damp from sweating have a fever be in shock or feel cold chilled Wipe area where electrodes will be placed with an alcohol swab if lotion has been used or subject...

Page 12: ...the clips and gently remove the electrodes being careful to not injure the skin 5 Use the Segmenal BIA software for analysis and printing reports Please note If test results seem unusual or inaccurate...

Page 13: ...body are displayed These values are the same as other RJL BIA analyzers right body measurement The Quantum V is now ready to start a segmental BIA scan initiated either with the ON button or the segme...

Page 14: ...er carefully The Analyzer can be damaged by rough handling i e shaking or being dropped The cables can be damaged if stepped on crushed tied in knots pulled on etc Always use caution when connecting a...

Page 15: ...hem with furniture pull on them etc Store them loosely coiled in the protective zippered pouch provided in the Analyzer kit Disconnect the cables from the analyzer by gently pulling on the connector t...

Page 16: ...ead 2 Test the analyzer Resistance measurement acceptable range is 495 0 to 505 0 ohms 500 0 is ideal Reactance measurement acceptable range is 003 0 to 003 0 ohms 0 Is ideal Readings within these ran...

Page 17: ...ting should be avoided on a subject with implanted electronic devices such as pacemakers or cardiac defibrillator ICD s BIA Analyzers introduce a small amount of alternating AC current into the body t...

Page 18: ...here electrodes are placed Use an alcohol swab to clean the area s let dry and use fresh electrodes Technician did not get accurate pre test information from the subject or neglected to ask about issu...

Page 19: ...RE EXCLUSIVE AND COMPRISE RJL S SOLE AND ENTIRE WARRANTY OBLIGATIONS AND LIABILITITES IN CONNECTION WITH THE EQUIPMENT AND SOFTWARE SOLD AND LICENSED HEREUNDER AND ARE IN LIEU OF AND EXCULDE ALL OTHER...

Page 20: ...o these costs before any work begins Cost of the repair service must be paid in full before the unit is shipped back to the customer If repairing the Analyzer is not cost effective RJL Systems will pr...

Page 21: ...21 APPENDIX...

Reviews: