Product Manual | Lynx™ Embedded Sensors LES‑B‑127‑50/125/500/2000
37
SENSOR INSTALLATION CHECK—CLAMP
PLATE (TYPICAL) INSTALLATIONS
Verify that the each sensor, transfer pin, and ejector pin pocket is machined correctly.
PRE‑ASSEMBLY CHECKS
1.
Indentation Test (with sensor)
With the clamp plate disassembled, sensor in place, and cover plate removed, push the
sensor and transfer pin forward; there should be 0.012–0.02” (0,3–0,5 mm) clearance
between the sensor bottom and the clamp plate/sensor pocket bottom before the cover
plate surface. Verify that the pin moves freely without any resistance.
2.
Flush Test (with sensor)
With the transfer pin, sensor, and cover plate installed, place the ejector plate above
the clamp plate, and position fully back. Verify that the counterbore depth equals 0.012”
(0,3 mm) and that the diameter is larger than the ejector pin head; the transfer pin should
be flush with the ejector retainer plate.
3.
Indentation Test (with Ejector Pin)
Clamp Plate
Clamp Plate
Cover Plate
Ejector Plate
Transfer Pin
Transfer Pin
Sensor
Sensor