![RJG Lynx LES-B-127-125 Product Manual Download Page 10](http://html.mh-extra.com/html/rjg/lynx-les-b-127-125/lynx-les-b-127-125_product-manual_1466485010.webp)
Lynx™ Embedded Sensors LES‑B‑127‑50/125/500/2000 | Product Manual
2
SENSOR AND EJECTOR PIN SIZE
SELECTION CHARTS
The charts below are only a guide. In order to assure correct sensor selection for your
application, please contact RJG.
Locate the pin size that will be used and match it to the location on the part (near the
end of fill or near the gate). The recommended sensor is the intersection of the row and
column.
1.
Imperial Units
NORMAL PRESSURE
HIGH PRESSURE
Pin Size
Sensor Model
Sensor Model
3/64
LES-B-127-50
LES-B-127-50
1/16
LES-B-127-50
LES-B-127-50
5/64
LES-B-127-50
LES-B-127-125
3/32
LES-B-127-125
LES-B-127-125
7/64
LES-B-127-125
LES-B-127-125
1/8
LES-B-127-125
LES-B-127-500
9/64
LES-B-127-500
LES-B-127-500
5/32
LES-B-127-500
LES-B-127-500
3/16
LES-B-127-500
LES-B-127-500
7/32
LES-B-127-500
LES-B-127-500
1/4
LES-B-127-500
LES-B-127-2000
9/32
LES-B-127-2000
LES-B-127-2000
5/16
LES-B-127-2000
LES-B-127-2000
11/32
LES-B-127-2000
LES-B-127-2000
3/8
LES-B-127-2000
LES-B-127-2000
13/32
LES-B-127-2000
LES-B-127-2000
7/16
LES-B-127-2000
LES-B-127-2000
1/2
LES-B-127-2000
-
9/16
-
-
5/8
-
-