background image

12

Diagnostic Messages / Regular Reminders

5. Diagnostic Messages / Regular Reminders

Diagnostic 

message

Meaning

Action required

No message displayed The power supply to the 
whirlwhirlwhirlpool controls is disconnected. 
Temperature not known.

The operator console remains switched off until the power is restored. The 
whirlpool controls settings are stored for up to 30 days with the assistance of 
a reserve battery.

0HH

"Overheat" - 
The whirlpool controls have switched themselves 
off. One of the sensors in the heating element has 
measured 48°C. 

Pointer to a defective filter pump or a block- 
age in the filter circuit.

DO NOT GET IN THE WATER! Remove the whirlpool cover and allow the water 
to cool. When the heating element has cooled down reset the system by 
pressing any button. If the whirlpool controls will not reset, disconnect the 
power and call the dealer or customer service. 

Check filter pump.

OH5

"Overheat" -The whirlpool controls had switched 
themselves off. One of the sensors in the heating 
element had measured 43°C. 
Pointer to a defective filter pump or a block- 
age in the filter circuit.

DO NOT GET IN THE WATER! Remove the whirlpool cover and allow the water 
to cool. At 43°C the whirlpool controls should automatically reset themselves. 
If the whirlpool controls do not reset, disconnect the power and call the 
dealer or customer service.  

Check filter pump.

ICE

"ICE" - additional sensor senses the danger of  
frost or  
a sensor wire is broken

No action necessary. The pump and blower are automatically activated, 
regardless of the whirlpool status.  
If necessary, replace sensor

SnH

The whirlpool is switched off. The sensor 
connected to temperature socket A is not 
working.

If the problem persists, notify the dealer or customer service. (Usually happens 
temporarily with overheating and disappears again, after the heater element 
has cooled down.)
If necessary, replace sensor

Snb

The whirlpool is switched off. The sensor 
connected to temperature socket B is not 
working.

If the problem persists, notify the dealer or customer service (Usually happens 
temporarily with overheating and disappears again, after the heater element 
has cooled down).  
If necessary, replace sensor

SnS

The sensors are not balanced. If this message is 
alternately displayed with the water temperature, 
it could be a temporary condition. If the message 
blinks alone, the whirlpool controls are switched 
off.

If the problem persists, notify the dealer or customer service. Check sensor 
and cartridge and replace as necessary. 

HFL

The temperature difference between the sensors 
is more than 2.5°C which usually points to a flow 
problem. 

In this case it could be due to air in a newly filled 
system.

Check the water level in the whirlpool. Add water as necessary. When there is 
enough water ensure the pumps are rinsed. If the problem persists, notify the 
dealer or customer service.
Bleed the system at the couplings on the heater.

LF

Permanent problem with too weak a flow (is 
displayed when the message "HFL" is displayed 
five times in 24 hours). The heating is switched 
off but the other whirlpool functions are running 
normally.
In this case it could be due to air in a newly filled 
system.

Same procedure as with message "HFL". The heater function of the whirlpool 
does not automatically reset, press any button to set it up anew.

Bleed the system at the couplings on the heater.

dr

Not enough water measured in the heater  
element.
In this case it could be due to air in a newly filled 
system.

Check the water level in the whirlpool. Add water as necessary. When there is 
enough water ensure the pumps are rinsed. Press any button to reset.
Bleed the system at the couplings on the heater.

dr4

Not enough water measured in the heater 
element (will be displayed when the message "dr" 
is displayed for the third time). The whirlpool is 
switched off.
In this case it could be due to air in a newly filled 
system.

Same procedure as with message "dr". The whirlpool controls do not reset 
automatically, press any button to reset.

Bleed the system at the couplings on the heater.

Pr

When switched on for the first time, the whirlpool 
controls run in rinse mode.

The rinse mode lasts up to 4 minutes and afterwards the whirlpool is heated 
and, in standard mode, the water temperature maintained.

Summary of Contents for Penta P

Page 1: ...l Information WP 10 B 09 2009 P O R T A B L E S P A S Vi tara V i ano Sienna Sienna XL P enta P Instructions for Installation and Use Pr e fa b r i c at e d Sw i m m i n g Po o l s Wh i r l p o o l s...

Page 2: ...2 8 7 Operating mode Page 7 2 8 8 Setting the time Page 7 2 8 9 Programming the filter optimally Page 7 2 8 10 Preset filter cycles Page 7 3 Care and maintenance 3 1 Water maintenance Page 8 3 1 1 Fil...

Page 3: ...ualified and approved electrician and in compliance with local regulations see diagram 1 2 The whirlpool should be filled using a water hose supplied by the customer The whirlpool itself has no connec...

Page 4: ...supply incapacitates the frost protection function so always be sure to empty the pool after switching off the power supply The LCD always displays the last recorded temperature Please note that the...

Page 5: ...e pool has only 1 massage pump The reversing valve on the side of the pool determines which jets are being activated when the pump runs Mid position The water flows through all jets evenly The valve s...

Page 6: ...his means that when the water pressure becomes too little the cartridge should be cleaned or replaced By pressing this button the air blower will be switched on and off The blower switches itself off...

Page 7: ...n the Set Time message flashes in the display To set the time press first warm Mode cool Blower Jet 1 Jet 2 Light then warm Mode cool Blower Jet 1 Jet 2 Light and finally warm Mode cool Blower Jet 1 J...

Page 8: ...he whirlpool s skim filter is fitted with very fine non woven filter cartridges which keep impurities out of the water The cartridge itself is capable of lasting many years but should be changed every...

Page 9: ...fection of the water in the whirlpool salt deposits build up To keep this build up as low as possible fresh water should be added This is why after every bath the whirlpool should be topped up to its...

Page 10: ...he surface must be rubbed down using fine sandpaper A tin of teak varnish is provided with every whirlpool If the Isola spa is not used during winter the following has to be observed The pool is set o...

Page 11: ...be spent in the water If the water is 36 C the bathing time should be approximately 20 minutes if the water is 38 C no more than 10 12 minutes Taking a break Each bath should be followed by a cool do...

Page 12: ...stomer service Usually happens temporarily with overheating and disappears again after the heater element has cooled down If necessary replace sensor SnS The sensors are not balanced If this message i...

Page 13: ...ays Clean and treat wood according to manufacturer s instructions rLH Every 365 days Install new filter F1 lit up Filter time 1 activated F2 lit up Filter time 2 activated PL lit up Button lock active...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...www pools de One of the leading German manufacturers of prefabricated swimming pools swimming pool technology...

Reviews: