background image

Practice 

Set “Snd 0” item in the service menu. 

Listen to the sound while returning to main menu. 

Look the upper right corner of the screen. 

Decrease ‘Energy’ to 1 and listen to the sound. 

Set “Snd 2” item in the service menu. 

Listen to the sound while returning to main menu. 

Look the upper right corner in the screen. 

Decrease ‘Energy’ to 1 and listen to the sound. 

Summary of Contents for SCENAR 1-NT

Page 1: ...SCENAR 1 NT The first steps RITM OKB ZAO ...

Page 2: ...MENU button Amplitude setting O state 2 sec without pressing Basis states DOSE button 2 sec without pressing buttons 2 sec without pressing ...

Page 3: ...The O state screen ...

Page 4: ...Each step of amplitude setting is indexed with click When min max of the amplitude is reached long signal sounds Sounds while amplitude setting ...

Page 5: ... dosing is off Every 30 sec without button pressing short signal sounds Sounds during work 30 sec 30 sec 30 sec ...

Page 6: ...The menu structure ...

Page 7: ... Dose mode Dose 1 No 2 3 АМ 4 5 Gap ...

Page 8: ... Dose mode Working in dose mode screen information and sounds will be observed later ...

Page 9: ... Amplitude modulation mode АМ FМ No 1 1 Bee 5 1 2 1 Dose ...

Page 10: ... No 1 1 2 1 3 1 4 1 5 1 Bee Sounds in Amplitude modulation mode ...

Page 11: ... Frequency modulation mode FМ Dmp No On Sw 4 Sw1 АМ ...

Page 12: ... Frequency modulation mode ...

Page 13: ...Sounds in Frequency modulation mode No On Sw1 Sw2 Sw3 Sw4 ...

Page 14: ... Damping mode Dmp No F FМ Sc1 Var Sc4 Sc2 ...

Page 15: ...Sounds in Damping mode No Sc1 Sc2 Sc3 Sc4 Var ...

Page 16: ... Frequency mode F Int 15 350 Dmp ...

Page 17: ... 15 3Hz 29 7Hz 59 3Hz 90 3Hz 121 Hz 180 Hz 351 Hz Sounds in Frequency mode ...

Page 18: ... Intensity mode Int 2 1 3 8 Gap F ...

Page 19: ... Gap mode Gap Dose 10 80 Int ...

Page 20: ...requency Switch on the combination FМ Var Switch on damping Sc4 Switch Dose mode Dose 1 Switch off the modulation Set intensity 2 3 8 While increasing Gap watch the intensity Switch the device off and switch it on again ...

Page 21: ... Dose mode 1 2 No contact nobody Contact ...

Page 22: ... Dose mode 1 2 1 sec ...

Page 23: ... Dose mode 1 2 The dose the zero ...

Page 24: ... Dose mode 3 initial coefficients of form initial reactions ...

Page 25: ... Dose mode 4 ...

Page 26: ... Dose mode 5 ...

Page 27: ...e comfortable influence level Switch Dose mode Dose 1 Set the device at the same skin area several times with the same pressing Watch the initial reaction Set the device at that skin area with different pressing Watch the initial reaction ...

Page 28: ...Practice Set the device at different skin areas watch the initial reaction Select the area with the max initial reaction Set the device at this area wait for dose and zero ...

Page 29: ...Service menu ...

Page 30: ...Service menu To enter the Service menu press the and buttons simultaneously and a rising beep will sound ...

Page 31: ...us state and the value of the highlighted parameter and this value solely is saved in the constant memory of the device If the value has been changed then a descending beep will sound So within the same menu entering you can change any number of parameters but only one parameter will be saved ...

Page 32: ... Auto Off AOff When the AOff is set to Off the automatic turn off is disabled This may cause faster battery exhaustion when you leave the device switched on for a long time ...

Page 33: ...f are given in the table Automatic turn off time when no buttons pressed AOff Nobody Contact Timer reset Off never never never only when buttons pressed On 30 sec never Every time the electrode contacts taken up from the skin 5m 5 min 10m 10 min 20m 20 min ...

Page 34: ...ght menu item is the time of screen back lighting for the following events pressing any button reaching the Dose or Zero expiration of the first second of measuring in the Dosing state or expiration of every 30 seconds ...

Page 35: ... Save Screen Save Scr The Save Scr menu item allows to save the current orientation of the image on the screen as default ...

Page 36: ... all sounds except for clicks while controlling the energy strength will be disabled and in the Basic state a corresponding indication will be displayed in the top line of the screen Snd 1 is for minimum sound volume Snd 2 for medium volume and Snd 3 for maximum volume ...

Page 37: ...o 5 sets of Stimulus Attributes Dose AM FM Dmp F Int and Gap To save the sets of parameters in one of 5 cells select the cell number and wait until the device exits the Service menu A descending beep will indicate that the settings have been saved ...

Page 38: ...des of stimulation from the constant memory Select the number 1 5 of the cell that contains your presettings saved earlier and wait until the device exits the Service menu A descending beep will sound and the settings will be applied And the energy strength will be automatically set to minimum ...

Page 39: ...Other settings The Cont menu item allows to control the image contrast The Lng menu item allows to select a language 2 languages are available Russian and English ...

Page 40: ...urning to main menu Place the device on the skin and take out several times watch the timer and skin contact indicator Select the service menu set AOff On Listen to the sound while returning to main menu Place the device on the skin and take out several times watch the timer and skin contact indicator ...

Page 41: ... Press button Switch the device off and switch it on again Select the service menu and watch AOff state Set AOff 5m and pass to the next item Watch the timer for more than 5 minutes Switch the device off and switch it on again Select the service menu and watch AOff state ...

Page 42: ...rning to main menu Look the upper right corner of the screen Decrease Energy to 1 and listen to the sound Set Snd 2 item in the service menu Listen to the sound while returning to main menu Look the upper right corner in the screen Decrease Energy to 1 and listen to the sound ...

Page 43: ...The certificates ...

Page 44: ...Russia ...

Page 45: ...Europe ...

Page 46: ......

Page 47: ...Other countries ...

Reviews: