Pub. No. 1120-R5 — June 2000
27
Problem
Probable Cause
Remedy
11. Unit will not recycle.
a. Power is disconnected.
a. Verify that power has not been
disconnected.
b. Damaged limit switch wand
b. Verify that both limit switch wands
or wands.
are straight and undamaged. Repair
or replace as needed.
c. One or both limit switches are
c. Verify proper operation of limit
defective.
switches.
d. Faulty electrical connections.
d. Have an electrician verify all elec-
trical connections.
e. LS1 and/or LS2 are not
e. See page 16 — ARTD Adjustments.
adjusted properly.
f. Debris in lip hinges.
f. Remove any debris.
12. During recycle, unit will not
a. LS1 and/or LS2 are not
a. See page 16 — ARTD Adjustments.
raise high enough to reset
adjusted properly.
into the lip keepers.
13. The unit goes into repeated
a. LS2 is not adjusted properly.
a. See page 16 — ARTD Adjustments.
partial platform cycles.
b. Lip falling too slow or not
b. See page 25 — Problem and
falling to full pendant position.
Remedy #2. See also page 14 —
Lip Assist Spring Adjustment.
APB-1000/Rev5 6/1/00 7:48 AM Page 27