1 - Place the three side elements vertically as in the image alongside.
2 - Using the round head screws provided, assemble the hexagonal struc-
ture. It is very important to assemble the three elements vertically and on
a surface that ensures excellent flatness so as to obtain a reliable support
surface for the closing flange.
Attention: The screw head must be placed
on the internal side of the foundation case.
See figure alongside.
3 - Before fixing the upper flange, insert the metallic protection of the 50
mm diameter corrugated pipe which must be set in the ground to make
the subsequent electrical connection with the control unit. See figures
alongside.