15
PREl
Enables or disables pre-flashing.
On: Pre-flashing enabled. The flashing output (7/8 and 12/13) is activated 3 seconds
before the motor starts (do not use with EFO device installed).
Off: Pre-flashing disabled.
(OFF)
nlsu
Enables/disables timed operation of bollards.
ON: Timed operation of the bollards (the operating time is defined by parameters TM1
and TM2).
OFF: operation with limit switch.
(OFF)
htr
Enables or disables the Human Present function.
On: Human Present function.
The DOWN/UP button must be kept pressed throughout the manoeuvre.
Off: Automatic operation.
(OFF)
efo
EFO (Emergency Fast operation) device operation
ON: operation for a bollard equipped with an EFO system. The STOP input becomes
a pressure switch input, the BLINK output controls the valve for the additional tank
(EFO).
OFF: normal operation.
(OFF)
Cvar
Enables or disables programmable code transmitters.
On: Radio receiver enabled exclusively for rolling-code transmitters.
Off: Receiver enabled for rolling-code and programmable (self-learning and dip/
switch) transmitters.
(ON)
REM
Enables or disables remote switching of radio transmitters (see REMOTE LEARNING
section).
On: Remote entry enabled
Off: Remote entry disabled
(ON)
RADIO (
RAD
)
MENU
FUNCTION
PP1
Selecting this function, the receiver waits (Push) for a transmitter code to be assigned to the step-step function for bollard 1.
Press the key of the transmitter you want to assign to this function.
If the code is valid, it is stored and the message OK is displayed.
If the code is not valid, the message Err is displayed.
PP2
Selecting this function, the receiver waits (Push) for a transmitter code to be assigned to the step-step function for bollard 2.
Press the key of the transmitter you want to assign to this function.
If the code is valid, it is stored and the message OK is displayed.
If the code is not valid, the message Err is displayed.
doun
Selecting this function, the receiver waits (Push) for a transmitter code to be assigned to the OPEN function (both bollards)
Press the key of the transmitter you want to assign to this function.
If the code is valid, it is stored and the message OK is displayed.
If the code is not valid, the message Err is displayed.
UP
Selecting this function, the receiver waits (Push) for a transmitter code to be assigned to the CLOSE function (both bollards)
Press the key of the transmitter you want to assign to this function.
If the code is valid, it is stored and the message OK is displayed.
If the code is not valid, the message Err is displayed.
CLR
Selecting this function, the receiver waits (Push) for a transmitter code to be deleted from the memory
If the code is valid, it is deleted and the message OK is displayed.
If the code is not valid or not stored in the memory, the message Err is displayed.
RTR
Completely deletes the memory of the receiver. Confirmation of the operation is requested.
When this function is selected, the receiver waits (Push) for a new PGM to confirm the operation.
At the end of the deletion, the message OK is displayed.
MANOEUVRES NUMBER (
Nma1
)
Displays the number of complete cycles (ascent) performed by the M1 bollard. The first press of the <PG> button displays
the first 4 digits, the second press the last 4. Ex. <PG> 0012 >>> <PG> 3456: 123,456 cycles made.
MANOEUVRES NUMBER (
Nma2
)
Displays the number of complete cycles (ascent) performed by the 2 bollard. The first press of the <PG> button displays the
first 4 digits, the second press the last 4. Ex. <PG> 0012 >>> <PG> 3456: 123,456 cycles made.