Rise MAX.CP Installation Manual Download Page 12

12

ITA

WARNING

The product shall not be used for purposes or in ways other than those for which the product is intended for and as described in this 
manual. Incorrect uses can damage the product and cause injuries and damages.
The company shall not be deemed responsible for the non-compliance with a good manufacture technique of gates as well as for any 
deformation, which might occur during use.
Keep this manual for further use. 
This manual has been especially written to be use by qualified fitters.
Installation must be carried out by qualified personnel (professional installer, according to EN 12635), in compliance with Good Practice 
and current code.
Make sure that the structure of the gate is suitable for automation.
The installer must supply all information on the automatic, manual and emergency operation of the automatic system and supply the 
end user with instructions for use.
Packaging must be kept out of reach of children, as it can be hazardous. For disposal, packaging must be divided the various types 
of waste (e.g. carton board, polystyrene) in compliance with regulations in force.
Do not allow children to play with the fixed control devices of the product. Keep the remote controls out of reach of children.
This product is not to be used by persons (including children) with reduced physical, sensory or mental capacity, or who are unfamiliar 
with such equipment, unless under the supervision of or following training by persons responsible for their safety.
Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and shearing hazard. 
Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the operating 
logic of the system and forces generated by the automated system.
Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453.
Only use original accessories and spare parts, use of non-original spare parts will cause the warranty planned to cover the products 
to become null and void. 
All the mechanical and electrical parts composing automation must meet the requirements of the standards in force and outlined by 
CE marking.
An omnipolar switch/section switch with remote contact opening equal to, or higher than 3mm must be provided on the power supply 
mains.
Make sure that before wiring an adequate differential switch and an overcurrent protection is provided.
Pursuant to safety regulations in force, some types of installation require that the gate connection be earthed.
During installation, maintenance and repair, cut off power supply before accessing to live parts.
Also disconnect buffer batteries, if any are connected.
The electrical installation and the operating logic must comply with the regulations in force.
The leads fed with different voltages must be physically separate, or they must be suitably insulated with additional insulation of at 
least 1 mm.
The leads must be secured with an additional fixture near the terminals.
During installation, maintenance and repair, interrupt the power supply before opening the lid to access the electrical parts
Check all the connections again before switching on the power.
The unused N.C. inputs must be bridged.

WASTE DISPOSAL

As indicated by the symbol shown, it is forbidden to dispose this product as normal urban waste as some parts might be harmful 
for environment and human health, if they are disposed of incorrectly. Therefore, the device should be disposed in special collection 
platforms or given back to the reseller if a new and similar device is purchased. An incorrect disposal of the device  will result in fines 
applied to the user, as provided for by regulations in force.

Descriptions and figures in this manual are not binding. While leaving the essential characteristics of the product unchanged, the manufacturer reserves the 
right to modify the same under the technical, design or commercial point of view without necessarily update this manual.

TECHNICAL DATA

Mains power

230 Vac +/- 10% 50/60 Hz

Motor output

1/2 MAX M30 series bollards | 1 MAX M30 EFO bollard

Maximum motor current

8A for each individual output

Accessory power supply output

24Vac 0.5A max.

Degree of protection

IP54

Operating temp.

-20°C / +60°C

Radio receiver

433.92 MHz built-in and configurable

No. of codes that can be stored

64

Summary of Contents for MAX.CP

Page 1: ...MAX CP Manuale di installazione Installation manual I Centrale di comando per 1 o 2 dissusasori Made in Italy GB 1 or 2 bollards control unit ITA GB 05 2021 rev 0 ...

Page 2: ...2 x2 345 mm 265 mm 130 mm 1 2 3 4 5 ...

Page 3: ...7 8 6 5 4 3 2 1 12 13 11 10 9 N L GND R A D I O Max 30Vac dc 1A Max 0 5A BLINK EFO E V BLINK EFO E V EV M EV M LSC1LSO1 LSC2LSO2 F10A F10A T100mA 6 7 COM OP CL PHO STP 24Vac AUX2 AUX1 MOT COM MOT MOT COM MOT 23 22 21 20 29 30 24 25 26 27 28 18 16 14 19 17 15 7 8 6 5 4 3 2 1 12 13 11 10 9 BLINK EFO E V BLINK EFO E V LSC1LSO1 LSC2LSO2 1 2 3 4 5 6 7 8 9 10 11 M 1 E V LSC LSO COM COMBL NOT USED LSO LS...

Page 4: ... 2 3 4 5 6 7 8 9 10 11 M 1 E V LSC LSO COM COMBL NOT USED 8 COM OP CL PHO STP 24Vac AUX2 AUX1 MOT COM MOT MOT COM MOT 23 22 21 20 29 30 24 25 26 27 28 18 16 14 19 17 15 7 8 6 5 4 3 2 1 12 13 11 10 9 EV EFO EV EFO LSC1LSO1 LSC2LSO2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5 M 5 1 E V LSC LSO E V 2 E V 3 EFO COM COMBL P 1 EFO P 2 FOT EMERGENCY PUSH BUTTON RELAY 230Vac 3 CONTACTS 1 5sec EMERGENCY PUSH BUT...

Page 5: ... 2 1 7 8 6 5 4 2 ON 1 3 2 1 12 13 11 10 9 EV EFO EV EFO LSC1LSO1 LSC2LSO2 1 2 3 4 5 6 7 8 9 10 M 1 E V LSC LSO COM COMBL 1 2 3 4 5 6 7 8 9 10 M 1 E V LSC LSO COM COMBL 230Vac STATUS DIP SWITCH LED2 BUZ2 LED1 COM COM COM COM BUZ1 AUT1 AUT2 T200mA AUX1 5 V1 V2 V1 V2 10 MAX CP MAX M30 1 CP BL optional MAX M30 2 CP BL optional ...

Page 6: ...Buona Tecnica l utilizzo l ambiente di installazione la logica di funzionamento del sistema e le forze sviluppate dall automazione L installazione deve essere fatta utilizzando dispositivi di sicurezza e di comandi conformi alla EN12978 e EN12453 Raccomandiamo di utilizzare accessori e parti di ricambio originali utilizzando ricambi non originali il prodotto non sarà più coperto da garanzia Tutte ...

Page 7: ...O2 Ingresso finecorsa apertura dissuasore abbassato dissuasore 2 31 32 Antenna Collegamento antenna scheda radioricevente incorporata 31 ANT segnale 32 SHIELD schermo FUSIBILI F1 F10A Protezione Motore 1 F2 F10A Protezione Motore 2 F5 T 100 mA Protezione Trasformatore Accessori PROGRAMMAZIONE La programmazione delle varie funzionalità viene effettuata utilizzando il display LCD presente a bordo de...

Page 8: ...alita del dissuasore 1 vedi schema di collegamento Fig 6 3 L uscita replica lo stato dell ingresso LSC1 4 L uscita inverte lo stato dell ingresso LSO1 5 Uscita comando scheda luci buzzer 0 5 5 Aux2 Imposta la modalità di funzionamento dell uscita ausiliaria 2 0 Contatto per collegamento spia stato dissuasore vedi schema collegamento AUX Spia accesa a dissuasore abbassato Spia intermittente frequen...

Page 9: ...codice trasmettitore da assegnare alla funzione passo passo per il dissuasore 1 Premere il tasto del trasmettitore che si intende assegnare a questa funzione Se il codice è valido viene memorizzato e viene visualizzato il messaggio OK Se il codice non è valido viene visualizzato il messaggio Err PP2 Selezionando questa funzione la ricevente si pone in attesa Push di un codice trasmettitore da asse...

Page 10: ...io di conferma CONF dopo alcuni secondi viene ri visualizzato il codice 0000 è necessario riconfermare il codice di protezione precedentemente inserito in modo da evitare inserimenti involontari Se il codice corrisponde al precedente viene visualizzato un messaggio di conferma OK La centrale esce automaticamente dalla fase di programmazione e per accedere nuovamente ai menu sarà necessario inserir...

Page 11: ... sui fermi meccanici non sono utilizzati i finecorsa magnetici Logica NLSW ON funzionamento a tempo Nessun lampeggio accesi fissi Funzionamento con finecorsa magnetici Logica NLSW OFF PHOT STOP EFO DOWN UP LSO1 LSC1 LSO2 LSC2 SMALTIMENTO Qualora il prodotto venga posto fuori servizio è necessario seguire le disposizioni legislative in vigore al momento per quanto riguarda lo smaltimento differenzi...

Page 12: ... the mechanical and electrical parts composing automation must meet the requirements of the standards in force and outlined by CE marking An omnipolar switch section switch with remote contact opening equal to or higher than 3mm must be provided on the power supply mains Make sure that before wiring an adequate differential switch and an overcurrent protection is provided Pursuant to safety regula...

Page 13: ... bollard 2 30 LSO2 Opening limit switch input bollard down bollard 2 31 32 Antenna Built in radio receiver board antenna connection 31 ANT signal 32 SHIELD shield FUSES F1 F10A Motor Protection 1 F2 F10A Motor Protection 2 F5 T 100 mA Transformer Protection Accessories PROGRAMMING The various functions are programmed using the LCD display on the control unit and by setting the desired values in th...

Page 14: ...us of input LSC1 5 Light buzzer board command output 0 5 5 Aux2 Sets the operating mode of auxiliary output 2 0 Contact for connection of bollard status light see AUX connection diagram Light on when the bollard is lowered Flashing light frequency 1 flash second with bollard in descent Flashing light frequency 2 flash second with bollard in ascent Warning light off with bollard raised 1 AUX 2 cont...

Page 15: ...step step function for bollard 2 Press the key of the transmitter you want to assign to this function If the code is valid it is stored and the message OK is displayed If the code is not valid the message Err is displayed doun Selecting this function the receiver waits Push for a transmitter code to be assigned to the OPEN function both bollards Press the key of the transmitter you want to assign ...

Page 16: ...NECESSARY TO CONTACT THE AUTHORISED TECHNICAL SERVICE CENTRE FOR A TOTAL RESET OF THE CONTROL UNIT TRANSMITTERS REMOTE LEARNING If you have a transmitter already stored in the receiver it is possible to carry out radio remote learning without having to access the control unit IMPORTANT The procedure must be carried out with the bollard down during the TCA break Proceed as follows 1 Press the hidde...

Page 17: ...ste dale seguenti direttive Direttiva 2014 53 EU Direttiva 2011 65 EU Sono state applicate le norme armonizzate e le specifiche tecniche descritte di seguito ETSI EN 300 220 1 V3 1 1 ETSI EN 300 220 2 V3 1 1 ETSI EN 301 489 1 V2 1 1 ETSI EN 301 489 3 V2 1 1 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 EN 60335 1 2012 A11 2014 EN 60335 2 103 2015 Il Certificato di Conformità di questo documento corr...

Page 18: ...elevant Union harmonization legislation Direttiva 2014 53 EU Direttiva 2011 65 EU The following harmonized standards and technical specifications have been applied ETSI EN 300 220 1 V3 1 1 ETSI EN 300 220 2 V3 1 1 ETSI EN 301 489 1 V2 1 1 ETSI EN 301 489 3 V2 1 1 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 EN 60335 1 2012 A11 2014 EN 60335 2 103 2015 The Certificate of Conformity in this document ...

Page 19: ...19 ...

Page 20: ......

Reviews: