9
When the configuration setting is One Push Button, only S1 input will be valid.
The control moving commands can be accepted in this switch type while the
shutter is moving. In this switch type, the inclusion/exclusion/reset/association
function can also be fulfilled by pressing S1 just like the operation of include
button.
When S1 is short pressed, the shutter will move up toward TOP(0xFF). While in
this moving S1 is short pressed again, the shutter will stop moving. A third short
pressing of S1 will move the shutter down toward BOTTOM(0x00). While in this
moving S1 is short pressed again, the shutter will stop moving. And so on…
Inverting direction and stopping.
7-5-2 Two Push Button
:
(The default setting is Two Push Button (2))
If this setting is configured as Two Push Button, S1 and S2 input will be valid, but
will not accept pressing S1and S2 at the same time. In this switch type, the
inclusion/exclusion/reset/association function can also be fulfilled by pressing S1
or S2 just like the operation of include button.
When S1 is pressed and hold more than 1.5 seconds, the shutter will move up
toward TOP(0xFF), and the shutter will stop moving when S1 is released. When
S2 is pressed and hold more than 1.5 seconds, the shutter will move down
toward BOTTOM(0x00), and the shutter will stop moving when S2 is released.
When S1 is short pressed, the shutter will move up toward TOP(0xFF). While
in this moving short pressed S1 again, the shutter just keep moving up toward
TOP(0xFF). The easy way to stop this moving is short pressing S2. When S2 is
short pressed, the shutter will move down toward BOTTON(0x00). While in this
moving short pressed S2 again, the shutter just keep moving down toward
BOTTON(0x00). The easy way to stop this moving is short pressing S1.
When in Two Push Button switch type, S1 or S2 are pressed and not
released, and PAN08 receive any control moving command from Z-Wave RF
(Ex. BASIC_SET
、
、
、
、
BINARY_SWITCH_SET
、
、
、
、
MULTILEVEL_SWITCH_SET
、
、
、
、
MULTILEVEL_SWITCH_START_LEVEL_CHANGE or
MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE or
SCENE_ACTIVATION_SET), PAN08 won’t do any change in position but
report alarm to Group1 (Alarm_Type=1, Alarm_level =0xFF), this indicate
that the S1 or S2 not been release.
ATT. : For avoid misunderstanding that RF command dose not work, it is
recommended to check the status of S1 and S2.
7-6 Level Report mode
Mode 1 : In 5 seconds period after controlled by a moving command, it will report the
destination level when received request command. Out of the 5 seconds
period, it will report the actual level of the shutter when received request
command.
Mode 2 : Whenever the shutter move pass a 10 percent level, it will auto report the
level to Group 1 node.
8
Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION_V2
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC