Installation and operation
1. Put the in wall PAN08 into a wall box and connect the AC power wire L,N to PAN08
connector L, N.
2. Connect the wall switch to the PAN08 as Fig1
3. To manually switch up and down of the shutter, simply press the external switch S1
or S2. The detail is described in 7-5.
4. PAN08 built in meter function and can read the Watt, KWh, V(Voltage), I(Current),
PF(Power Factor) of the load by using Z-Wave command class, user can set a
threshold current to get the warning caused by abnormal operation
5. PAN08 have overload protection function, and can help to prevent short circuit
caused by load.
Programming
1. Basic Command Class
The PAN08 will respond to BASIC and BINARY commands that are part of the
Z-Wave system.
1.1 BASIC_GET
When PAN08 receive Basic Get Command, it will send Basic Report Command
to report the position of the shutter. When the report value is 0x00, that mean the
shutter is at the Bottom, if the report value is 0x63 or 0xFF that mean the shutter
is at the Top, any other value between 0x01~0x62 imply Shutter at the position
between top and bottom.
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command
:
[Command Class Basic, Basic Report, Value = 0x00 (BOTTOM)]
[Command Class Basic, Basic Report, Value = 0x01~0x62 (Between
BOTTOM and TOP)]
[Command Class Basic, Basic Report, Value = 0x63/0xFF (TOP)]
1-2 BASIC_SET
PAN08 can accept Basic Set Command which value is either (0x00) Bottom or
Top (0x63/0xFF) or (0x01-0x62) the position between TOP and Bottom. Other
value (0x64-0xFE) is not acceptable.
[Command Class Basic, Basic Set, Value = 0x63 or 0xFF] control the
shutter to the top (0xFF)
[Command Class Basic, Basic Set, Value = 0x00(0)] control the shutter to
the bottom(0x00)
[Command Class Basic, Basic Set, Value = 0x01-0x62] control the shutter
to the position between bottom and top
2
Binary Switch Command Class
2-1 BINARY_SWITCH_GET,
When PAN08 receive Binary Switch Get Command, it will send Binary Switch Report
Command to report the position of the shutter. When the report value is 0x00, that