Risco PAN08-1B Manual Download Page 10

10 

* COMMAND_CLASS_SWITCH_MULTILEVEL_V3 
* COMMAND_CLASS_CONFIGURATION 
* COMMAND_CLASS_ALARM 
* COMMAND_CLASS_METER_V3 
* COMMAND_CLASS_SCENE_ACTIVATION 
* COMMAND_CLASS_SCENE_ACTUATOR_CONF 
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 
 
 
 

Troubleshooting 
                                 

 

Symptom 

Cause of Failure 

Recommendation 

The PAN08 not working 
and LED off 

1.  The PAN08 is not 

connect to the Main 
power 

2.  The PAN08 break 

down 

1.  Check power connections 
2. Don’t open up the PAN08 and send 

it for repair. 

The shutter move direction 
is reverse 

Wrong connection of NC 
and NO to the motor   

Swap the NC NO connection 

PAN08 LED light work fine 
But can not control 

1. No association setting 
2. Same frequency 

interference 

3. S1 or S2 are pressed in 

Two Push Button switch 
type, PAN08 would not 
accept RF command.   

1. Carry out association 
2. Wait for a while to re-try 
3. Release S1 and S2 

 

 

Specification 
 

Operating Voltage

 

100 ~240VAC 

Maximum Load 

Resistive load 5A max 

Range 

Minimum 30 m in door 100m outdoor line of sight 

Operating Temperature  0°C ~ 40°C 
Frequency Range 

PAN08-1: 868.40MHz; 869.85MHz(EU) / 
PAN08-2: 908.40MHz; 916.00MHz(USA/Canada) / 
PAN08-3: 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP) 

** Specifications are subject to change and improvement without notice.                           

 

 

 

 

Warning: 

1.Plug out to disconnect from power supply; Do not plug in line.

 

 

2. Do not exceed the max rating 

 

Disposal   

 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to 
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling. 

Company of License Holder

Philio Technology Corporation

 

Address  of  License  Holder

8F.,No.653-2,Zhongzheng  Rd., Xinzhuang  Dist.,  New  Taipei City 

24257,Taiwan(R.O.C) 

 

 

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

 

This equipment has been tested and found to comply with the limits for 

a Class B digital device, pursuant to Part 15 of the FCC Rules. These 

limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses 

and can radiate radio frequency energy and, if not installed and used 

in accordance with the instructions, may cause harmful interference to 

radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this equipment 

does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one of the following 

measures:

 

Summary of Contents for PAN08-1B

Page 1: ...WaveTM Network In the front casing there is an include button with LED indicator below which is used to carry out inclusion exclusion reset or association When first power is applied its LED flashes...

Page 2: ...elease yet No node ID Under normal operation when the PAN08 has not been allocated a node ID the LED flashes on and off alternately at 2 second intervals By pressing S1 S2 or Include button it will st...

Page 3: ...ter is at the Bottom if the report value is 0x63 or 0xFF that mean the shutter is at the Top any other value between 0x01 0x62 imply Shutter at the position between top and bottom Basic Get Command Co...

Page 4: ...AN08 can accept Multilevel Switch Set Command which value is either 0x00 Bottom or Top 0x63 or 0xFF or 0x01 0x62 the position between TOP and Bottom Other value 0x64 0xFE is not acceptable Command Cla...

Page 5: ...and that will automatically calibrate this error 3 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE When receive Multilevel Switch Stop Level change Command PAN08 will stop the motor 4 SCENE ACTIVATION COMMAN...

Page 6: ...nsumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Comman...

Page 7: ...nd Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF It mea...

Page 8: ...Report Period If the setting is configured for 1hour set value 720 the PAN08 will report its instant power consumption every 1 hour to the node of Group 1 The maximum interval to report its instant p...

Page 9: ...oving short pressed S1 again the shutter just keep moving up toward TOP 0xFF The easy way to stop this moving is short pressing S2 When S2 is short pressed the shutter will move down toward BOTTON 0x0...

Page 10: ...king indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recyc...

Page 11: ...t 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferen...

Reviews: