Risco PAN08-1B Manual Download Page 1

PAN08-1B/-2B/-3B    Roller shutter controller

 

         

   

 

 

Fig 1. Assembling 

 

 
The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter 
connected to its terminals using radio waves, controllers and a push button directly 

connected to this Roller Controller. 
This in-wall Roller Shutter Controller is a transceiver which is a Z-Wave Plus

TM

 

enabled device and is fully compatible with any Z-Wave

TM

 enabled network. Slim 

design let the Controller can easily hide itself into the wall box and that will be good 
for the house decoration.   
The new smart relay calibration technology can reduce the inrush current caused by 
the load and let the module work perfectly with many kind of Roller Shutter.     
This in-wall Roller Shutter Controller is able to detect position of the Shutter by using 
the patterned power measuring method, so it can be remote controlled not only fully 
up  or  down  ,  but  also  can  be  adjusted  to  ex.  30%  or  50%.  And  when  manual 
controlled by push button, the controller also can memorize the position and send the 
new shutter position to its controller (ex. IP-Gateway).

 

 

 

Adding to Z-Wave

TM

 Network

 

 
In the front casing, there is an include button with LED indicator below which is used 
to carry out inclusion, exclusion, reset or association. When first power is applied, its 
LED flashes on and off alternately  and repeatedly  at  0.5 second  intervals. It  implies 
that it has not been assigned a node ID and start auto inclusion.   
 
Auto Inclusion 
 
The function of auto inclusion will be executed as long as the PAN08 does not have   
Node ID and just connect the PAN08 to main power. 
 
Note:
 Auto inclusion timeout is 2 minute during which the node information of 
explorer frame will be emitted once every several seconds. Unlike “inclusion” function 
as shown in the table below, the execution of auto inclusion is free from pressing the 
Include button on the PAN08. 
 
The table below lists an operation summary of basic Z-Wave functions. Please refer 
to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the 

Setup function, and to include/exclude/associate devices 
 

Function 

Description 

LED Indication 

No node ID 

The Z-Wave Controller does not allocate 
a node ID to the PAN08. 

LED 2-second on, 2-second 
off 

Inclusion 
(Add a new node) 

1.  Put your Z-Wave controller into 

inclusion mode by following the 
instructions provided by the 
controller manufacturer. 

One press one flash LED 

Summary of Contents for PAN08-1B

Page 1: ...WaveTM Network In the front casing there is an include button with LED indicator below which is used to carry out inclusion exclusion reset or association When first power is applied its LED flashes...

Page 2: ...elease yet No node ID Under normal operation when the PAN08 has not been allocated a node ID the LED flashes on and off alternately at 2 second intervals By pressing S1 S2 or Include button it will st...

Page 3: ...ter is at the Bottom if the report value is 0x63 or 0xFF that mean the shutter is at the Top any other value between 0x01 0x62 imply Shutter at the position between top and bottom Basic Get Command Co...

Page 4: ...AN08 can accept Multilevel Switch Set Command which value is either 0x00 Bottom or Top 0x63 or 0xFF or 0x01 0x62 the position between TOP and Bottom Other value 0x64 0xFE is not acceptable Command Cla...

Page 5: ...and that will automatically calibrate this error 3 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE When receive Multilevel Switch Stop Level change Command PAN08 will stop the motor 4 SCENE ACTIVATION COMMAN...

Page 6: ...nsumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Comman...

Page 7: ...nd Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF It mea...

Page 8: ...Report Period If the setting is configured for 1hour set value 720 the PAN08 will report its instant power consumption every 1 hour to the node of Group 1 The maximum interval to report its instant p...

Page 9: ...oving short pressed S1 again the shutter just keep moving up toward TOP 0xFF The easy way to stop this moving is short pressing S2 When S2 is short pressed the shutter will move down toward BOTTON 0x0...

Page 10: ...king indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recyc...

Page 11: ...t 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferen...