background image

G

G

G

G

T

T

T

T

4

4

4

4

9

9

9

9

0

0

0

0

X

X

X

X

C

C

C

C

o

o

o

o

n

n

n

n

tt

tt

rr

rr

o

o

o

o

ll

ll

  

  

P

P

P

P

a

a

a

a

n

n

n

n

e

e

e

e

ll

ll

User Instructions

PR5847 Rev11 490X User Guide.qxd  10/05/2012  11:01  Page 1

Your local installer: www.eaglesecuritysolutions.co.uk

Summary of Contents for gt490x

Page 1: ...G G G GT T T T4 4 4 49 9 9 90 0 0 0X X X X C C C Co o o on n n nt t t tr r r ro o o ol l l l P P P Pa a a an n n ne e e el l l l User Instructions Your local installer www eaglesecuritysolutions co uk ...

Page 2: ......

Page 3: ...omm Programming 17 19 Using Vo Comm 20 Messages from Vo Comm 20 User Initiating Remote Access 21 Resetting After An Alarm 22 23 Setting Engineer Authorisation 25 G Tag Introduction 27 Programming G Tag 27 Using G Tag 27 Display Status Blanking 28 Keypad Tamper 28 Keypad Alert 28 System Tampers 28 Mains Failure 29 Setting The System With Mains Fail 29 30 Re setting The Display After A Mains Fail 30...

Page 4: ...pad 1 Location Keypad 2 Location Keypad 3 Location Keypad 4 Location G Tag 1 Location G Tag 2 Location Keyswitch Location if fitted Reserved User Code User No Installation Company Name Installation Company Address Installation Company Tel Fax Other Information Note This section to completed by the installation engineer ...

Page 5: ... User Code Types Master Level User Code BS EN2 default 5678 Five Levels of User Codes are available on the GT490X each user code type allows for different levels of access In total 15 User codes may be programmed by a Master Level User Code User number 1 will always be a Master Level User but the remaining 14 User Codes may be programmed by a Master Code to the required level of access These may b...

Page 6: ...it time to 3 seconds Note G Tag Proximity Tags may be used for setting and unsetting the system Please refer to the Using G Tag section for instructions Note Depending on the level of your system and the legislation that it is required to comply with your installation company may have initialised Display Blanking When this is used the Status of the system will only be indicated on the display for ...

Page 7: ... If the No key is pressed or you take longer than 20 seconds the display will return to the time and date Setting Unsetting the System via a Keyswitch if fitted One of two types of keyswitch es may have been fitted to your system Normal To set the system with a normal keyswitch insert the key and turn to the ON position then remove the key Follow the instructions from step 3 above To unset insert ...

Page 8: ...on for instructions Part Setting The System using Master Main type codes 1 With the display showing 2 Enter a Master or Main type code the display will show for example 3 Press 1 2 or 3 for Part 1 2 or 3 the display will show for example Note Your installation company will have informed you what zones are being removed omitted for the Part Set you are using Refer to the System Attributes section f...

Page 9: ...s or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop if the exit tone has been audible or a single beep will be emitted if the exit tone has been silent 6 The system is now Part Set you are free to move around the zones that have been removed by the Part Set but other zones on the system are active ...

Page 10: ...pressing NO will un remove a zone The display will show 6 Repeat step 5 until you have removed all the required zones 7 Press 0 to escape the display will show 8 Press YES the continuous exit tone will sound 9 Exit the premises via the authorised exit route the exit tone will change as detectors are violated When the premises are secure listen that the exit tone returns to the continuous tone Wait...

Page 11: ...splay will show 7 Then for example 8 Pressing 1 will enter zone Status mode All zones will show on the display and will be deleted as each zone is triggered Press 0 to escape Pressing 6 will silence the internal sounder Pressing 4 will toggle the Strobe On Off Pressing 9 will toggle the Bell On Off 01 JAN 18 58 01 Do you want to SET the System Do you want to REMOVE Zones Do you want to TEST the Sy...

Page 12: ...esting the system press 0 twice the display will show Viewing The Event Log Master code only 1 With the display showing 2 Enter a Master Code the display will show for example 3 Press NO three times the display will show 4 Press YES the display will show for example 01 JAN 18 58 01 01 JAN 18 58 01 Do you want to SET the System Do you want to View the LOG Read Log 01 JAN 18 58 01 ...

Page 13: ...t day 6 When you have finished viewing the Log press 0 twice The display will show Changing The Chime Status Master code only The Chime zones will have previously been programmed by the installation company A Master level code may change the status of the Chime between On and Off To do so proceed as follows 1 With the display showing 2 Enter a Master Code the display will show for example 3 Press ...

Page 14: ...ES the display will show for example Or 5 Press NO to change the status of the Chime then press YES the display will show 6 Press 0 to escape the display will show Chime is Off ok Chime is On ok Do you want to Change Chime 01 JAN 18 58 01 ...

Page 15: ...y these keyswitches If your engineer has indicated see pages 2 37 that some of the user numbers on your system have been reserved you should not use them whilst programming user codes If you do so your system may be adversely affected 1 With the display showing 2 Enter a Master Code the display will show 3 Press NO five times the display will show 4 Press YES the display will show 5 Enter the user...

Page 16: ... section for details 9 Press YES The display will show This determines if using this user code to Set or Unset the system will trigger the Vo Comm For more details on Vo Comm please refer to the Vo Comm section Press NO until the setting you require is displayed YES or NO Note The Vo Comm will need to be programmed in order for this option to work please refer to the Vo Comm section in this manual...

Page 17: ... position 13 Continue entering characters up to 9 If you require a blank space press YES while the is displayed 14 As you press YES for the ninth character or if you have jumped from step 9 the display will change to 15 If you wish to program other User Codes return to step 4 Or Press 0 to return to Do you want to Prog USER CODES 01 JAN 18 58 01 1 2 3 4 5 6 7 8 9 0 YES NO ABC DEF GHI JKL MNO PQR S...

Page 18: ... then press YES 7 Display will show Press YES 8 Display will show 9 Enter the Day Month ie 0706 for 7th June followed by YES The display will show 10 Enter the time using 24Hr Clock ie 23 30 for 11 30pm followed by YES the display will show 11 Press 0 the display will show 01 JAN 18 58 01 Do you want to SET the System Do you want to Set DATE TIME Summer Adjust is On ok Year is 2005 ok Year is 2005...

Page 19: ...s that the Vo Comm will dial Before Vo Comm can work several options will need to be programmed Please read below for information Vo Comm Programming if fitted 1 With the display showing 2 Enter a valid Master Level Code 5678 default Display will show 3 Press NO 7 times Display will show 4 Press YES Display will show 5 Press NO until display will shows 6 Press YES Display will show Or for example ...

Page 20: ... ID for the premises 00 to 99 followed by YES This Site ID will identify what system is calling you 18 Display will show To change this press NO until the required setting On or Off is displayed then press YES The term Open relates to the system being Unset With Open Reporting turned On the Vo Comm will report the system being opened Unset for all users who have had the attribute of Vo Comm Trigge...

Page 21: ...rigger On allocated in the User Code Programming 20 Options available are Off No system Close are reported Full Set Only Full Sets are reported Any Set All Sets Full Part are reported Press NO until your required setting is shown then press YES Display will show 21 Press NO this is dealt with in the using Vo Comm section The display will show 22 Press 0 to return to Close Reporting Off Make an Ala...

Page 22: ... on your telephone keypad twice A rising tone will be heard that indicates that the call has been acknowledged If you do not acknowledge the call or hear the rising tone the Vo Comm will repeat the message several times and then go on to dial the remaining telephone numbers until the call is acknowledged Messages From Vo Comm Two types of message will be sent by Vo Comm Either a status message or ...

Page 23: ...he Remote Call follow the instructions below 1 Negotiate with your installation company when you should initiate the Remote Call 2 With the display showing 3 Enter a Master Code the display will show 4 Press NO seven times the display will show 5 Press YES the display will show until dialling commences then until connection then 6 When your installation company has finished the display will show N...

Page 24: ...ay will show if the system is unset If the system is set enter your code to unset it 2 Press the NO key to view the cause of the Alarm or Fault Note If NO is NOT pressed then the alarm status will only be displayed for ten seconds 3 The display will then show Enter your user code again 4 The display will show 5 Press 0 The display will show 6 Press the NO key to view the cause of the alarm or faul...

Page 25: ...er your user code again 3 The display will show Press the Reset key Or 4 Press YES The exit tone will sound and the display will show for example 5 Enter the code again to abort the setting 6 The system is now reset Or If a higher level of code is required one of the following displays will be shown Use a Master code to reset the system Or Call the installation company Or Call the central station ...

Page 26: ... station or engineer as instructed by the installation company and quote the number given by the display 8 The central station or engineer will give a return Anti Code this may contain the YES NO keys for example 5 YES 2 4 9 Enter this Anti Code into the keypad 10 The system is now reset ...

Page 27: ...selected no user authorisation will be required to grant engineer access to the alarm system However the panel will generate an audible sound for approximately 8 seconds to indicate that the engineer is on site 4 Press YES The display will show This option is dealt with later 5 Press YES The display will show 6 Press 0 to return to Using Engineer Authorisation A valid Authorisor code will be requi...

Page 28: ... Press NO The display will show 6 Press YES The display will show 7 Press 0 to return to Provided that the next code entered is a valid engineer code access will be granted to him her without further user intervention Do you want to SET the System Do you want to Authorise Engnr Engnr Authorisor Any Engineer Access is Off Ok Engineer Access is On Ok Do you want to Authorise Engnr 01 JAN 18 58 01 ...

Page 29: ...ple Follow the instructions for programming User Codes onto your system up to the point when you would enter the User Code At this point present you Tag to the Proximity Reader and a code will be entered for you Continue with the instructions entering the User Name etc Each G Tag will be identified on an individual basis when it is used to Set or Unset the system 4 Wire Keypad Each G Tag need only...

Page 30: ...by the engineer when pressed together will act as alert keys The exact function will depend on what they have been programmed for But for example if they are programmed as panic pressing them will activate the alarm when the system is set or unset Keypad Tamper The keypad will monitor the number of attempts without a valid User Code being entered More than seven attempts will cause a keypad tamper...

Page 31: ...nder At this point it is essential that you contact your installation company Setting the system with Mains Fail In the event of a short term power cut where it is known when power will be restored e g Engineers working on power lines that affect your premises it might be necessary to set this system Please follow the steps outlined below 1 With the display showing Note In the event of a mains pow...

Page 32: ... The right arrow is now indicating that more events are available for viewing Press the YES key to view the next event and carry on to view any others When viewing the last event the display will show for example The left arrow now indicates that you are at the end of events The NO key may be used to scroll back the opposite way 3 Enter your User code again The display will then show Followed by Y...

Page 33: ... level Follow the normal instructions for programming codes At the Point when you are asked for the Level choose Control When asked for the Code Group enter 1 to 8 your installation company will have given you what group to use Then choose Can or Cant Unset dependant on your requirements Follow the normal instructions to the end for programming codes Using Advanced Codes Two typical uses for Advan...

Page 34: ...ystem If extra copies are required the manual may be downloaded from our web site www riscogroup co uk Testing Servicing Your System The system you have installed will give many years of service but it should be tested and serviced on a regular basis by a qualified installation engineer It may be a condition of your insurance policy and or your Police response that it is serviced at regular interv...

Page 35: ...Page 33 GT490X User Manual Notes ...

Page 36: ...Page 34 GT490X User Manual Notes ...

Page 37: ... Attributes Control Panel Zones Zone No Zone Type Descriptors Part Info Example E E Front Door 1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Radio Zones If Fitted Zone No Zone Type Descriptors Part Info 91 92 93 94 95 96 97 98 Zone Notes ...

Page 38: ...Page 36 GT490X User Manual Service Record Date Comments Signature Alarm Reset Type Tamper Reset Type Service Company Tel Fax Service Notes ...

Page 39: ...g User Name User 1 User 2 User 3 User 4 User 5 User 6 User 7 User 8 User 9 User 10 User 11 User 12 User 13 User 14 User 15 Note Under no circumstances should you write down the actual code Radio Fob Users If Used In Use User Name User 81 User 82 User 83 User 84 User 85 User 86 User 87 User 88 Use this space to record any codes that have been reserved for Keyswitch es ...

Page 40: ...k Middleton Manchester M24 2SS United Kingdom Internet www riscogroup com e mail sales riscogroup co uk Risco Group UK Ltd reserve the right to amend the software and features without prior notice PR5847 Rev1 1 5IN490UM B Your local installer www eaglesecuritysolutions co uk ...

Reviews: