background image

 

 

7

EN

LEDS INDICATION

LEDS INDICATION

LEDS INDICATION

LEDS INDICATION    

 Key 

 Function 

   

  

(Blue)

 

 Communication with the panel 

 

(Red)

 

 On

: Fully or partially set 

 Slow flash

: Exit delay 

 Rapid flash

: Alarm 

(Yellow)

 

 Fault in the system while the system is unset.  

SLEEP MODE

SLEEP MODE

SLEEP MODE

SLEEP MODE    

For extending the battery life of the keypad, the keypad is designed with a Sleep mode 
function. By default, 10 seconds after the last key has been pressed, the keypad will 
turn off its display and LEDs. The time can be configured by your engineer to a 
maximum of 60 seconds. 

BATTER

BATTER

BATTER

BATTERY

Y

Y

Y    ACTIVATION

ACTIVATION

ACTIVATION

ACTIVATION

    

Remove the batteries red strip to activate the batteries.  

 

 

CAUTION: 

Risk of explosion if battery is replaced by an incorrect type. Dispose of 

used batteries according to local regulations. 

CHANGING KEYPAD PARAMETERS

CHANGING KEYPAD PARAMETERS

CHANGING KEYPAD PARAMETERS

CHANGING KEYPAD PARAMETERS    

Any change performed in the definition of the keypad parameters requires to update 

the keypad as well. This is performed by pressing the 

 key for 2 seconds. Doing so, 

the panel will send an update to the keypad.

 

Summary of Contents for Agility 2-way Wireless LCD Keypad

Page 1: ...tents Table of Contents INTRODUCTION 4 MAIN FEATURES COMMUNICATION SETUP 4 MOUNTING THE KEYPAD 5 MAIN USER OPERATIONS 6 COMMON OPERATIONS 6 KEY OPERATION DURING PROGRAMMING MODE 6 ADVANCED OPERATIONS LEDS INDICATION 7 SLEEP MODE 7 REPLACING BATTERIES 7 CHANGING KEYPAD PARAMETERS 7 TECHNICAL SPECIFICATION 8 2W WL LCD Keypad 915 ...

Page 2: ... at the control panel If the control panel is not already in Learn mode press the button on the control panel for 5 seconds the unit beeps once as it enters Learn mode all the LEDs also light up one after the other Make sure batteries are installed in each keypad before allocating them Send a signal transmission from the keypad by pressing and simultaneously for at least 2 seconds the control pane...

Page 3: ...munication with the system 1 Release the Mounting bracket captive screw 1 Figure 1 2 Slide up the Main Unit 3 to release it from the two mounting bracket s locking tabs 2 3 Mount the bracket Figure 2 4 Release the battery cover screw 1 and place the supplied 3 batteries 5 Close the battery compartment and mount the keypad to the mounting bracket in a reverse sequence to the removal 1 Tamper Figure...

Page 4: ...ollowed by code or proximity tag Full Unset Disarm Press followed by code or proximity tag 1 Consult your engineer for the operations defined with a code 2 For optimal use of the proximity tag use it from a distance of 1 2 cm from the center of the keypad s door 3 For Part Setting Away Arming with no entry delay press the key for two seconds KE KE KE KEY OP Y OP Y OP Y OPERATION DURING PROGRAMMING...

Page 5: ... display and LEDs The time can be configured by your engineer to a maximum of 60 seconds BATTER BATTER BATTER BATTERY Y Y Y ACTIVATION ACTIVATION ACTIVATION ACTIVATION Remove the batteries red strip to activate the batteries CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to local regulations CHANGING KEYPAD PARAMETERS CHANGING KEYPAD PARAM...

Page 6: ... s authority to operate the equipment FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in ...

Page 7: ...defective Product and repair or have repaired the defective Product or ii accept return of the defective Product and provide a replacement product to the customer The customer must obtain a Return Material Authorization RMA number from RISCO prior to returning any Product to RISCO The returned product must be accompanied with a detailed description of the defect discovered Defect Description and m...

Page 8: ... particular purpose For the sake of good order and avoidance of any doubt DISCLAIMER EXCEPT FOR THE WARRANTIES SET FORTH HEREIN RISCO AND ITS LICENSORS HEREBY DISCLAIM ALL EXPRESS IMPLIED OR STATUTORY REPRESENTATIONS WARRANTIES GUARANTEES AND CONDITIONS WITH REGARD TO THE PRODUCTS INCLUDING BUT NOT LIMITED TO ANY REPRESENTATIONS WARRANTIES GUARANTEES AND CONDITIONS OF MERCHANTABILITY FITNESS FOR A...

Page 9: ...urglary robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Customer understands that a correctly installed and maintained alarm may only reduce the risk of burglary robbery or fire without warning but is not an assurance or a guarantee that such an event will not occur or that there will be no personal injury or property loss as a result thereof ...

Reviews: