background image

CHeCKlIst Before fIllInG your 

swIm spa 

Important: The equipment should never be operated 

without water in the swim spa. Serious damage to the 

equipment will occur. 
1. Installing your cover: Your Riptide swim spa cover 

comes with tie-down straps and locking hardware to 

attach the cover to the swim spa cabinet or decking. 
2.  Check  drain  valves:  Check  that  the  swim  spa 

drain valve is fully closed. 
3.  tighten  equipment  fittings:  In  the  equipment 

compartment,  hand-tighten  all  PVC  pipe  unions, 

pump  bleed  valve  and  pump  drain  plugs  to  prevent 

the  possibility  of  leakage  (sometimes  these  fittings 

loosen  during  shipment).  Check  also  that  all  fittings 

on the filter are closed (HAND TIGHT ONLY! ).
4. Check valve: Verify that all valves aside from the 

drainage valves described previously are in the fully 

open position. A valve that is half closed will result in 

InsTallaTIOn & seT-uP 

a noisy pump due to lack of water flow. 
5. fill the pool: Fill the swim spa to approximately 

the halfway point on the skimmers. 
note 1: The higher the water level, the less pool users 

it  will  take  to  cause  the  water  to  overflow  the  pool 

edge.  Also,  water  will  splash  out  more  easily  whilst 

swimming in the pool if it is over filled. 
note  2:  If  you  live  in  a  hard  water  area  and  have 

access to awater softener, you can fill the pool with a 

50/50 mix of hard and soft water. The calcium balance 

should be between 250 and 500 parts per million.
6.  Check  for  leaks:  After  the  Riptide  swim  spa  is 

full,  but  before  turning  the  power  on,  check  all  the 

fittings and equipment in the equipment compartment 

for  signs  of  leakage.  If  a  leak  is  detected,  except 

from  fittings  that  can  be  hand-tightened,  call  your 

authorised Riptide dealer.

Auxiliary Control Panel

Suction 

Panel

Weir 

/ Filter

Counter

Current

Main

Control

Panel

5

Summary of Contents for Manta SuperPro

Page 1: ...Owner s Manual Riptide Nautilus SuperPro Manta SuperPro Swim Spas Exercise Pools 2012 Euro 240v 50 Htz...

Page 2: ...ump 8 Ozone Generator 8 Auxiliary control panel 9 Diverter controls 9 User Preferences 9 Editing User Preferences 9 TROUBLESHOOTING GUIDE Diagnostic Messages 10 Periodic Reminder Messages 12 Diagnosti...

Page 3: ...gs or medication can greatly increase the risk of fatal Hypothermia in a swim spa b The causes symptoms and effects of Hypothermia may be described as follows Hypothermia occurs when the internal temp...

Page 4: ...ed to concrete wood non slip tile or linoleum Outdoor Considerations When selecting an outdoor site several things should be considered Firstly avoid selecting a site where excessive water may contact...

Page 5: ...ully open position A valve that is half closed will result in INSTALLATION SET UP a noisy pump due to lack of water flow 5 Fill the pool Fill the swim spa to approximately the halfway point on the ski...

Page 6: ...an automatic timer switch and operational safety features to ensure a safe and relaxing swim spa experience Heater control You can set the water temperature to suit the activity hot for just relaxing...

Page 7: ...de Both the Std and Ecn icons display in this mode During this time you can press the Mode button to revert back to Economy mode immediately Sleep mode heats the water to 11 C only during filter cycle...

Page 8: ...F2 icon will light when filter 2 is running If you would like to select continuous filtration set the filter 1 start and end times to be the same In this case the filter 2 start time only operates whe...

Page 9: ...nces The left 2 characters before the decimal point tell you what setting you are viewing or editing The character after the decimal point tells you the value of that setting for example Y for yes n f...

Page 10: ...nuer to operate normally The control panel will be disabled until power returns The clock time may have to be reset after reconnection All other spa settings will be preserved DO NOT ENTER THE WATER R...

Page 11: ...r level in spa Add water if necessary If the water is at the correct level make sure the pumps have been primed Press any button to reset The priming mode will last up to 4 minutes and the spa will be...

Page 12: ...ery 180 days Every 180 days Every 365 days As required Test and adjust pH chemical levels as per manufacturer s instructions Test and adjust sanitiser chemical levels as per manufacturer s instruction...

Page 13: ...ault time setting has switched of the jets The pump motor is overheating Water pump is sucking in air Filter cartridge needs cleaning There is no cover on the spa creating heat loss Heater is faulty J...

Page 14: ...LORINE SHOCK MAINTENANCE 3 pH Control Proper pH balance is extremely important in controlling bacteria providing water that s comfortable for the user and in preventing damage to the swim spa and its...

Page 15: ...the range of 7 4 7 6 6 After the water has circulated for approximately a quarter of an hour retest the chlorine level in your water and add the correct amount to raise the level to between 3 5 PPM S...

Page 16: ...Bisulphate pH Reducer 119 54g 239 09g 358 63g 478 18g 597 72g 717 26g 836 81g 956 35g 1075 90g 1195 44g 4 981 Increase Sodium Bicarbonate Alkalinity Increaser 99 62g 199 24g 298 86g 398 48g 498 10g 59...

Page 17: ...and gradual breakdown of headrest material due to the corrosive effect of chlorine and ozone CHANGING YOUR SWIM SPA WATER Depending on usage your spa section water will need to be changed approximate...

Page 18: ...is being used less than once per month then you may wish to lower the temperature MAINTENANCE setting of the spa section by approximately 5 C Lowering the temperature on your spa will cut your cost o...

Page 19: ...someone other than an authorised Riptide technician will not be covered by your warranty NON GUARANTEE SERVICE We recommend having an authorised Riptide technician perform all repairs on swim spa tha...

Page 20: ...be free from defects in materials and workmanship for a period of one year from the Swim Spa s delivery date Riptide Pools Limited United Kingdom 5Year Structural 5Year Surface Warranty Riptide warra...

Page 21: ...a when purchased and originally installed or relocated in the boundaries of the country of purchase The Riptide swim spa warranty terminates upon any transfer of ownership or if the swim spa is instal...

Page 22: ...Robjohns Road Chelmsford Essex CM1 3AG United Kingdom If possible please enclose a photocopy of the original purchase contract receipt to negate the need for inspection on service calls Name Address P...

Reviews: