16
Safety Timer
ON 120min
Capacity Cut-Off
ON 5000mAh
Input Power Low
Cut-Off 10.0V
Completion Ring
Beep 5
Key Beep OFF
Buzzer ON
Watt Limit (W)
CHG: 80
You can set a Watt limit for the charge rate between 60W and 80W.
When the charge process starts,the integrated safety timer starts to run simultaneously. If an
error is detected or the termination circuit cannot detect whether the battery is fully charged
or not. This unit is programmed to prevent overcharging. Please refer to the statement (shown
right) to calculate the timer you should set.
The program provides maximum capacity protection. If the Delta peak voltage cannot be
detected or the safety timer times out, the charge process will stop automatically when the
battery reaches the user-set maximum charge capacity.
This function monitors the voltage of the input battery used to power this charger.
If the voltage is lower than the user-set value, the program will end forcibly to protect the input
battery.
This setting sets the amount of beeps the charger speaker plays when the selected charge/
discharge function completes.
The beep confirms the users’ operation sounds every time a button is pressed.
The beep or melody sounds at various times during operation to confirm different mode
change. These functions can be switched on or off.