5.4.8. Protocol 8: Gedge C2
Character
Number
0
1
2
3
4
5
6
7
8
9
10
11
12
Description
S
TX
W
e
igh
t(0
)
W
e
igh
t(1
)
W
e
igh
t(2
)
W
e
igh
t(3
)
W
e
igh
t(4
)
W
e
igh
t(5
)
W
e
igh
t(6
)
W
e
igh
t(7
)
S1
S2
S3
Ig
n
o
re
Character
Number
13
14
15
Description
SPC
SPC
E
TX
Function
Description
STX
Start of Transmission Character (ASCII 02H).
Weight(0-7)
The numbers to be displayed on the remote display. These
eight characters can include a decimal point and a leading
minus to indicate sign. E.g.
(00000300) with leading zeroes would represent 300 units.
(00003.00) Is another acceptable string, this time with a
decimal point instead of one of the characters.
(-0003.00) Here we have the weight with the sign attached.
Note because of the sign and the decimal point only six
number characters are sent.
S1
Can be G or N to indicate Gross or Net respectively.
S2
Can be M or S to indicate Motion or Stable respectively
S3
Can be I,O or U to indicate In scale, Over range or Under
range respectively.
SPC
Space character (ASCII 20H).
ETX
End of Transmission character (ASCII 03H).
Summary of Contents for D32 series
Page 1: ...D32x XD30 Remote Display Manual D300 601 200...
Page 45: ...Remote Display Installation Manual Software Version 4 x D300 602 202 Page 45 Notes...
Page 46: ...Remote Display Installation Manual Software Version 4 x Page 46 D300 602 202 Notes...
Page 47: ...Remote Display Installation Manual Software Version 4 x D300 602 202 Page 47 Notes...
Page 48: ...Remote Display Installation Manual Software Version 4 x Page 48 D300 602 202...