10
Value Series Manual
Unit clearances
* 0 inches from vent components and condensate
drain line.
The clearance for servicing is 24 inches in front of the
water heater.
For closet installation, clearance is 6 inches (152 mm)
from the front.
Indoor models: V75i, V65i
Outdoor models: V75e, V65e
The clearance for servicing is 24 inches in front of the
water heater.
to Combustibles
inches (mm)
to Non-
Combustibles
inches (mm)
Top of Heater
12 (305)
2 (51)
Back of Heater
0 (zero)
0 (zero)
Front (Panel)
24 (610)
0 (zero)
Front (Exhaust)
24 (610)
24 (610)
Sides of Heater
6 (152)
1/8 (3.2)
Ground/Bottom
12 (305)
2 (51)
to Combustibles
inches (mm)
to Non-
Combustibles
inches (mm)
Top of Heater
6 * (152)
2 *(51)
Back of Heater
0 (zero)
0 (zero)
Front of Heater
6 (152)
6 (152)
Sides of Heater
2 (51)
1/2 (13)
Ground/Bottom
12 (305)
12 (305)
Vent
0 (zero)
0 (zero)