HE Series Infrared Gas Heater Installation and Operation Manual

 

#

 

PART DESCRIPTION

 

PART #

 

PART DESCRIPTION PRIMARY

 

MODEL (BTUH)

 

1

 

BURNER HOUSING:      

 

906000067

 

Burner housing coated gray

 

HE Series

 

2

 

BURNER CUP

 

906000068

 

Burner Cup 40,000

 

40 NG & LP

 

3

 

AIR RESTRICTOR RING

 

906000069

 

Burner Cup air restrictor ring 

-

 

9/32”

 

40 NG & LP

 

4

 

MAIN BURNER ORIFICE                NG

 

906000070

 

Gas orifice low intensity HR 31 DMS

 

40,000 NG

 

  

MAIN BURNER ORIFICE              LPG

 

906000071

 

Gas orifice low intensity HR 49 DMS

 

40,000 LP

 

5

 

BURNER CHAMBER

 

906000072

 

Burner Chamber 

 

All

 

6

 

AIR RESTRICTOR 

 

906000073

 

Burner air restrictor

 

40 NG & LP

 

7

 

EQUALIZER PLATE                         NG

 

906000074

 

Outlet equalizer plate 40,000 

-

 13 Holes

 

40 NG & LP

 

8

 

BLOWER GASKET

 

906000075

 

Blower gasket 

-

 Outlet

 

Each

 

9

 

AIR INTAKE SCREENED RESTRICTOR

 

908000012

 

Air Intake Restrictor 

-

 

1.5” 

Hole

 

40 NG & LP

 

10

 

BLOWER

 

908000013

 

Blower Assembly Tube Burner

 

  

11

 

MANIFOLD BUSHING

 

906000076

 

Manifold bushing

 

  

12

 

90 DEGREE ELBOW FITTING 1/2"

 

906000077

 

Street elbow fitting 90 deg 

 

  

13

 

GAS VALVE 

-

 NG

 

906000078

 

Gas Valve comb 3.5" WC 24VAC VR8 NG

 

40,000 NG

 

  

GAS VALVE 

-

 LPG

 

906000079

 

Gas Valve comb 10" WC 24VAC VR8 LP

 

40,000 LPG

 

14

 

4" NIPPLE 

 

906000080

 

Nipple 4"

 

  

15

 

TERMINAL BLOCK

 

905000018

 

Terminal block 

-

 Electrical Connections

 

  

16

 

STEP DOWN TRANSFORMER

 

905000019

 

Transformer 120/24V, 20VA 

 

  

17

 

COMPONENT PLATE

 

909000117

 

Component mounting plate SE

 

  

18

 

IGNITION CONTROL

 

905000020

 

Fenwal 3

-

Trial 24Vac with blower relay

 

Also see kit next 

page

 

19

 

COMBUSTION AIR PROVING SWITCH

 

905000021

 

Air Proving Switch 1.00" WC

 

  

20

 

BLOCKED FLUE PROVING SWITCH

 

905000022

 

Blocked Flue Switch 0.46" WC

 

 

21

 

PRESSURE SWITCH TUBING

 

906000081

 

Tubing set 2 x 20" PVC SE 

 

 

22

 

INDICATOR LAMPS

 

See Next Page

   

 

33. REPLACEMENT PARTS LIST

 

BURNER

 

Summary of Contents for RHE1S40N

Page 1: ......

Page 2: ...y result causing prop erty damage personal injury or loss of life Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other gas fired appliance WHAT TO D...

Page 3: ...Horizontal Vent 20 21 Horizontal Vent Terminal Location 22 Vertical Vent Through Roof 23 12 COMBUSTION AIR REQUIREMENTS 24 13 GAS SUPPLY CONNECTION 25 ORIENTATION OF FLEXIBLE GAS CONNECTION if applic...

Page 4: ...4 HE Series Infrared Gas Heater Installation and Operation Manual...

Page 5: ...adults should be alerted to the hazards of high sur face temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same...

Page 6: ...4 in USA and as indicated in this manual Refer to Sections 11 12 WARNING Start Up SMOKE Condition During start up the heating of material coatings used in the production process of tubes and reflector...

Page 7: ...be posted either adjacent to the heater thermostat or in the absence of such thermostat in a conspicuous location In addition to stored or stationary material consideration must also be given to move...

Page 8: ...FIGURE 1 MINIMUM CLEARANCES TO COMBUSTIBLES 3D VIEW Table 1 also lists values next page TUBE REFLECTOR MOUNTED UP TO 30 ANGLE EITHER DIRECTION TUBE REFLECTOR MOUNTED HORIZONTALLY Always maintain at le...

Page 9: ...a nearby surface The stated clearance to combustibles represents a surface temperature of 117F 65C above room temperature It is the installer s responsibility to ensure that building materials with a...

Page 10: ...T inches cm The minimum clearance to combustibles below this heater C is 53 inches 1346 cm Subtract C 53 inches 1346 mm from T Height above floor to get value H Enter the calculated value H on the sig...

Page 11: ...r other flammable material should not be placed on or near the appliance Any safety screen or guard removed to service an appliance must be replaced prior to operating the appliance Installation and r...

Page 12: ...be protected from damage by aircraft and other objects such as cranes and movable scaffolding D Heaters must be located so as to be accessible for servicing and adjustment 2 LABOR REQUIRMENTS Two pers...

Page 13: ...he minimum clearances between the heater and combustibles as shown in FIG 1 TABLE 1 Pages 8 9 It is the installer s responsibility to ensure that building materials with a low heat tolerance which may...

Page 14: ...burner housing MODEL GUIDELINE MOUNTING HEIGHT ft m DISTANCE HEATER LONG AXIS PARALLEL TO WALL HORIZONTAL ft m ANGLE MOUNTED HE Series 8 12 2 4 3 7 5 12 1 5 3 7 MINIMUM COMBUSTIBLE CLEARANCE BEHIND 1...

Page 15: ...end the heat er from a structural member that can adequately support the weight of the heater Always maintain the required minimum clearances to combustible ma terials and vehicles see pages 7 to 10 I...

Page 16: ...a structural member s of sufficient strength and integrity to support the weight of the heater 7 The heater comes fully assembled from the factory For locations where there is con strained access for...

Page 17: ...Series Infrared Gas Heater Installation and Operation Manual FIGURE 5 HEATER DIMENSIONS Turbulators factory installed in tube Burner side tube 39 99 cm FIGURE 6 HEATER SUSPENSION HORIZONTAL UP TO 30...

Page 18: ...ter The attachment of suspension hardware to the structure will be as required by site structural condi tions installation codes and or local engineering specifications Other types or systems of re st...

Page 19: ...wances for heater expansion must be made in the venting Improper installation can result in property damage injury or death This heater has a positive vent pressure A vent termination cap is recommend...

Page 20: ...apters Field Supplied Allow free expansion and contraction of the system and free flow of vent gas A wall thimble is not required through a non combustible wall Seal pipe penetration Seal all vent con...

Page 21: ...p see clearance information previous page and next page Install the termination cap a minimum of 6 inches 15 cm from the outside wall to the inside edge of terminal opening to minimize back pressure c...

Page 22: ...rom center of terminal 9 23 cm E Below an unventilated soffit 3 7 6 cm F To an outside corner 12 30 cm G To an inside corner 12 30 cm H To each side of centerline extended above a meter regulator asse...

Page 23: ...or insulated with a suitable material as approved and specified by the insulation manufacturer to withstand tem perature up to 460 F 238 C Use an approved B vent termination cap as supplied by the ma...

Page 24: ...l and national codes ANSI Z223 1 NFPA 54 in the USA The HE Series is an ap pliance approved as a Vented Overhead Heater under ANSI Z21 86 CSA 2 32 Vented Gas Fired Space Heating Appliances TEST FOR LE...

Page 25: ...uge con nection immediately upstream of the gas supply connection to the heater The gas supply should be checked first with heater turned OFF followed by an other check with heater turned ON This appl...

Page 26: ...ay be used Refer and ad here to local code requirements and NFPA 54 Section 9 6 in the USA If a flexible gas connector is used it must be installed in the orientation shown in Figure 14 be low as requ...

Page 27: ...mostat TruTemp Thermostat or 24V controller signal must be used for the post purge feature to function A line voltage Thermostat or an ON OFF switch will disable the post purge feature A maximum night...

Page 28: ...ation to ensure no debris is blocking the vent and that the integrity and construction of the vent piping is sound and no leakage is occurring 4 Visually inspect the burner flame periodically to ensur...

Page 29: ...WIRING DIAGRAM FENWAL S87J PAGE 30 CHANNEL MICRO 50N PAGE 31 24V OR 120 VOLT THERMOSTAT SINGLE HEATER PER THERMOSTAT NOTE Heater must be controlled by 24Vac Thermostat to enable post purge by the igni...

Page 30: ...30 HE Series Infrared Gas Heater Installation and Operation Manual 20 MULTIPLE TUBE HEATERS per THERMOSTAT Fenwal DSI P N 905000020...

Page 31: ...t any time less than the 1 hour auto reset recovery from lockout requires a manual reset by either resetting the thermostat or removing 24 volts for a period of 5 seconds Flame Failure Re Ignition If...

Page 32: ...ATION Proper location of the electrode assembly is important for optimum system performance The electrode assem bly should be located so that the spark gap is inside the flame envelope about 1 inch 2...

Page 33: ...OMMENDED ACTION S 1 Dead A Miswired check electrical supply 120Vac 5 B Transformer bad 24Vac 10 C Fuse Circuit breaker bad D Bad control check LED for steady on 2 Thermostat on no blower output A Misw...

Page 34: ...34 HE Series Infrared Gas Heater Installation and Operation Manual This Page Intentionally Left Blank...

Page 35: ...35 HE Series Infrared Gas Heater Installation and Operation Manual This Page Intentionally Left Blank...

Page 36: ...36 HE Series Infrared Gas Heater Installation and Operation Manual This Page Intentionally Left Blank...

Page 37: ...37 HE Series Infrared Gas Heater Installation and Operation Manual This Page Intentionally Left Blank...

Page 38: ...38 HE Series Infrared Gas Heater Installation and Operation Manual This Page Intentionally Left Blank...

Page 39: ...39 HE Series Infrared Gas Heater Installation and Operation Manual This Page Intentionally Left Blank...

Page 40: ...al on the Ignition Control to establish a spark Pull the wire away from the stud and note the length of gap at which spark discontinues A spark length of 1 8 in 3 mm or more indicates satisfactory vol...

Page 41: ...GNITER IS SHORTING OUT CHECK GROUND WIRING REMOVE AND INSPECT IGNITER AND LEAD CHECK BOOT OF THE IGNITION CABLE FOR SIGNS OF MELTING OR OVERHEATING IF YES TAKE PROTECTIVE ACTION TO SHIELD CABLE AND BO...

Page 42: ...DOWNS EVEN THOUGH OPERATION IS NOR MAL AT THE TIME OF CHECKOUT CHECK FOR EXCESSIVE HEAT AT SENSOR INSU LATOR AS TEMPERATURES ABOVE 1000 F 538 C CAUSES SHORT TO GROUND CHECK FLAME SIGNAL IN SERIES WITH...

Page 43: ...S ARE COMPATIBLE WITH THIS HEATER AND TO THIS EQUIPMENT HAS BEEN FACTORY FIRED AND TESTED PRIOR TO SHIPMENT HOWEVER THIS APPLIANCE IS NOT PLUG PLAY IT RE QUIRES COMMISSIONING AND FIELD ADJUSTMENT SPEC...

Page 44: ...EADING AT THE IGNITION MODULE VOLTS WHAT IS THE FLAME SIGNAL STRENGTH IN uA FROM SENSOR uA microamps IS HEATER CONTROLLED BY A THERMOSTAT YES NO IS THE THERMOSTAT STRATEGICALY LOCATED YES NO WHAT IS T...

Page 45: ...mm x 305 mm Burner Weight 26 pounds 11 8 kg Dimensions 16 L x 10 25 W x 10 75 H 406 mm x 260 mm x 273 mm Tube Reflector System Weight 60 pounds 27 kg Dimensions 103 5 L x 16 5 W x 7 5 H 2629 mm x 420...

Page 46: ...elow 31 HIGH ALTITUDE INSTALLATION Field Conversion Kit required to convert between fuel gas types Part number 903000039 HE Series Natural Gas to Propane Gas Conversion Kit Part number 903000040 HE Se...

Page 47: ...Safety Snap Hooks 2 pkg of 25 pkg of 100 903000071 903000064 903000070 TruTemp Infrared Setback Thermostat True comfort control for radiant heating systems senses and averages ambient and radiant temp...

Page 48: ...The pins that extend from each side of the two guard sections are inserted into these sets of holes Fig 1 Fig 2 Step 1 On ONE SIDE of the reflector remove the bottom screws Qty 3 that fasten the refle...

Page 49: ...e screws at the bottom edge of the reflector into the three hangers Fig 7 Fig 9 Fig 10 Center Fig 11 End Notes 1 To bend the pins use needle nose pliers to hold the guard screen securely Fig 8 and ano...

Page 50: ...ESTRICTOR 908000012 Air Intake Restrictor 1 5 Hole 40 NG LP 10 BLOWER 908000013 Blower Assembly Tube Burner 11 MANIFOLD BUSHING 906000076 Manifold bushing 12 90 DEGREE ELBOW FITTING 1 2 906000077 Stre...

Page 51: ...LECTRICAL CORD 905000028 Cord electrical 6 24 IGNITION SPARK CABLE See Above 25 IGNITER KIT 906000082 Spark Igniter Gasket Kit 26 SIGHT GLASS ASSEMBLY 909000118 Sight glass assembly tube heater 27 FLA...

Page 52: ...Positions tube in hanger reflector system 31 PREFORMED U TUBE 906000147 Preformed U Tube 17 ft tube length 32 HANGER 909000134 System Hanger 33 REFLECTOR 906000131 Reflector 34 REFLECTOR END PLATE 90...

Page 53: ...53 HE Series Infrared Gas Heater Installation and Operation Manual NOTES...

Page 54: ...54 HE Series Infrared Gas Heater Installation and Operation Manual NOTES...

Page 55: ...55 HE Series Infrared Gas Heater Installation and Operation Manual NOTES...

Page 56: ......

Reviews: