Infinity REU-2007,2008,2408,2424
- 1 -
©Rinnai
)* +
The brand name Infinity refers to “Endless Hot Water”. The Infinity series has been developed in
response to the growing changes in the lifestyle of consumers, and the increasing diversification and
sophistication of demand in the marketplace.
The Infinity series offers reduced cost, advanced safety features, and an option to connect one, two,
or three remote control pads.
The Infinity series is delivered with the maximum hot water temperature of 55
o
C, with or without
remote controls connected.
The Heavy Duty 20 is ideally suited for commercial or hydronic situations, as it is possible to obtain
a maximum outgoing hot water temperature of 75 C (with remote control connected) or 85 C
(without remote control connected) - see page 16 for details on requirements for setting the Heavy
Duty 20 to provide 85 C outgoing hot water.
$(,
The front cover of each appliance in the new series is formed from 0.6 mm coated steel, secured to
the main box assembly by 4 screws. Seals around the front cover and flue outlet prevent water from
entering the appliance.
Air inlets are situated in the front panel. The general layout of components is shown on the cutaway
diagram on page 9 to page 10. All components are supported within a box formed from 0.8 mm
coated steel.
The heat exchanger occupies the top section of the box, and the burner is situated in a chamber
formed from 0.8 mm aluminised steel attached to the bottom of the heat exchanger.
The air for combustion is supplied by a fan which is connected to the burner box by a duct at the left
hand side of the appliance.
Gas and water controls are situated at the bottom right of the appliance, directly under the manifold.
The products of combustion are expelled from the appliance through a flue outlet situated on the
front of the appliance, at the top.
The burner assembly is made up of 18 identical stainless steel bunsen burners, secured by an
aluminised steel framework. An aluminium manifold with 18 integrally moulded injectors supplies
gas to the burners, and is attached to the lower front cover of the burner box.
There is one thermistor, it is located on the outgoing hot water supply tube, near the outlet of the
heater.
°
°
°
Summary of Contents for REU-2007W
Page 1: ...INFINITY...
Page 8: ...Infinity REU 2007 2008 2408 2424 3 Rinnai 1 2 Note All dimensions are in mm...
Page 14: ...2 4 9 9...
Page 15: ......
Page 16: ...Infinity REU 2007 2008 2408 2424 11 Rinnai 2 4...
Page 31: ...Infinity REU 2007 2008 2408 2424 26 Rinnai 3 A A 6 4 8...
Page 32: ...Infinity REU 2007 2008 2408 2424 27 Rinnai 4 2 A Normal Combustion Sequence...
Page 62: ...Infinity REU 2007 2008 2408 2424 57 Rinnai 5 2 4...
Page 63: ...Infinity REU 2007 2008 2408 2424 58 Rinnai...
Page 64: ...Infinity REU 2007 2008 2408 2424 59 Rinnai...