Only alter gas type positions when converting. For conversion instructions refer to page 49.
* #; !
1* ' &4
There are different positions, depending on the temperature limit required and whether the remote
controls are connected or not.
2!,!4 / #++/<
40
C
43
C
50
C
55
C
60
C
65
C
75
C
85
C
(Heavy Duty 20 only)
(* , =,> +
40
C
43
C
50
C
50
C
55
C
60
C
65
C
75
C
If dip switches 6, 7 & 8 are set to any of the positions shown above and the remotes become
disconnected, the outgoing water temperature will automatically default to the temperature set on
switches 3, 4 & 5 (as shown above).
We recommend that switches 3, 4 & 5 be set to the OFF position to ensure a 55
C default setting. This
will provide a safe default temperature if the remote controls become disconnected.
Note: Check to see whether the by-pass tube has not been squeezed or cut-off. If so, the unit is not suitable
for use in the 55
C default mode.
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
Without
Remote
With
Remote