Infinity REU-2007,2008,2408,2424
- 48 -
©Rinnai
D.
Can not adjust
water temperature.
4.
Check water flow
servo.
i) Measure resistance
between red-blue water
flow servo connector I
1
.
10 ~ 30
Yes
Go to D-4-ii).
No
Replace water flow
servo with sensor.
42
ii) Measure voltage
between orange (+) -
grey (-) water flow servo
connector I
1
.
DC11~13V
Yes
Go to -4-iii).
No
Replace PCB.
43
iii) Measure voltage
between brown-grey
water flow servo
connector I
1
(don’t turn
water ON).
DC4 ~ 6V
Yes
Go to D-4-iv).
No
Replace water flow
servo with sensor.
44
iv) Measure voltage
between yellow-grey
water flow servo
connector I
1
(don’t turn
water ON).
Is voltage < DC
0.5V
Yes
Normal
No
Replace water flow
servo with sensor.
45
E.
Anti-frost heater
does not work.
1.
Check anti-frost
heater.
i)
*
Disconnect
connector J
3
; measure
resistance between blue-
blue (water valve)
950~1050
(2424,2408,2008)
590~600
(2007)
Yes
Go to E-1-ii).
No
Replace anti-frost
heater (assy).
46
ii)
*
Disconnect
connectors J
3
; measure
resistance between blue-
blue. (heat exchanger).
135~170
Yes
Go to E-2.
No
Replace anti-frost B
(assy).
47
2.
Check frost
sensing switch.
Disconnect connector f
3
;
measure the resistance
between blue-blue.
Atmospheric
temperature less than
4
C.
Is resistance <
1
Yes
Check wiring.
No
Replace frost
sensing switch.
48
Nature of Fault
Examination
Point
Diagnostic Point
Values
Y/N
Action
Repair
N
o
Ω
Ω
Ω
Ω
± °
Ω
Summary of Contents for REU-2007W
Page 1: ...INFINITY...
Page 8: ...Infinity REU 2007 2008 2408 2424 3 Rinnai 1 2 Note All dimensions are in mm...
Page 14: ...2 4 9 9...
Page 15: ......
Page 16: ...Infinity REU 2007 2008 2408 2424 11 Rinnai 2 4...
Page 31: ...Infinity REU 2007 2008 2408 2424 26 Rinnai 3 A A 6 4 8...
Page 32: ...Infinity REU 2007 2008 2408 2424 27 Rinnai 4 2 A Normal Combustion Sequence...
Page 62: ...Infinity REU 2007 2008 2408 2424 57 Rinnai 5 2 4...
Page 63: ...Infinity REU 2007 2008 2408 2424 58 Rinnai...
Page 64: ...Infinity REU 2007 2008 2408 2424 59 Rinnai...