55
Working maximum temperature CH
80
°C
Temperature range CH (mode: flow heating mode / space heating mode)
35-80 / 5-40
°C
Working maximum pressure DHW - PMS
10
bar
Working minimum pressure DHW (portata nominale)
0.7
1.1
1.2
bar
Activation minimum load DHW
2.0
l/min
Temperature range DHW
35-60
°C
Rated flow DHW (ΔT=25°C)
13.5
16.3
19.6
l/min
Rated flow DHW (ΔT=30°C)
11.2
13.6
16.3
l/min
Rated flow DHW (ΔT=35°C)
9.6
11.6
14.0
l/min
Maximum smoke temperature
85
°C
Exhaust temperature @ rated flow CH (80-60°C)
73
73
73
°C
Exhaust temperature @ min flow CH (50-30°C)
45
45
45
°C
Exhaust temperature @ rated flow & max temperature DHW
66
66
66
°C
Exhaust temperature @ min flow DHW & min flow DHW
45
45
45
°C
Exhaust temperature@ rated output CH (80-60°C)
11.7
13.6
17.0
g/s
Mass flow @ min flow CH (50-30°C)
2.8
2.8
4.0
g/s
Mass flow @ rated flow & max temperature DHW
11.7
13.6
17.0
g/s
Mass flow @ min flow DHW & min flow DHW
2.8
2.8
4.0
g/s
Exhaust flue system diameters (intake-discharge)
Coaxial system: Ø60/100
Parallel system: Ø80-80, Ø60-60
mm
Device type
B23, B53,C13, C33, C53, C63, C83, C93
C(10)3, C(12)3, C(13)3, C(15)3
-
Protection class IP
IPX5D
-
Activation power
13
13
19
kW
Max. Time for starting attempt (TSA)
4.0~6.0
s
Receptacle dimensions CH / DHW / Gas
20A / 15A / 15A
Dimensions (A x L x P)
660 × 440 × 285
660×440×335
mm
Weight (unladen)
33
37
Kg
Electricity supply
230 / 50
V/Hz
Electric fuses (internal)
3.0
A
Electrical absorption (CH / DHW)
83 / 85
100 / 105
95 / 98
W