![background image](http://html.mh-extra.com/html/rinnai/reb-kbi2424ff/reb-kbi2424ff_user-and-installation-manual_1462465027.webp)
27
1.6 MAINTENANCE
Annual specific maintenance is required in order to preserve the boiler’s entirety and to maintain
safety, performance and reliability characteristics unchanged: always contact your Rinnai
authorised technical assistence center.
The control panel and the appliance must be repared and maintained only by the specialized
and authorised techinical personnel of Rinnai: no partial or full repair by private household that
requires the opening of the device’s frontal panel is allowed.
The spare parts used for the maintenance must be original Rinnai parts.
Rinnai provides a technical support network with qualified and trained staff to provide you the best
service about Rinnai products, available on the website:
www.rinnai.it
It is recommended to previously take note of the boiler’s model and the serial number before
contacting Rinnai: this information will help us to understand the matter quickly and to ensure the
best possible service.
The appliance must be clean.
The boiler must be electrically isolated and the gas valve closed before
every kind of maintenance or cleaning can be performed.
Clean the outer boiler’s case and the remote control with cloth pieces,
moisted with water or non-aggressive detergents. Do not use solvents or
dispersants.
Always check the appliance and make sure nothing is accidentally
disconnected or damaged, on completion of the maintenance phase: leakage
produced by combustion can cause death or searious health disease to
people and animals.
Cleaning the domestic water filter
The boiler has a mesh filter situated on the inlet connection of the cold water.
This filter requires occasional cleaning: the frequency is determined by the
quantity of water used by the boiler system. The customers can clean this
filter independently and regularly, in order to keep the proper functioning of
the device inaltered, by limiting failure and damage causes.
To clean the filter
:
•
elettrically isolate the boiler, unplugging it from the main;
•
close the water vaves;
•
open the tap (hot water) and drain the circuit;
•
unscrew the mesh filter taking care not to damage it;
•
clean it by washing it with cold water;
•
reassemble and follow the same procedure backwards.
When the filter is dirty or clogged by debris, the entire performance is
reduced.
IMPORTANT
COIN