39
2.6.4 ELETTRICAL CONNECTION
IMPORTANT
Connect the boiler to a 230V ±10% / 50Hz power supply.
Do not use the gas or hydraulic lines for the grounding.
The electricity safety is ensured only when the device is provided with an appropriate grounding
and when the grounding system has been realized according to the safety requirements envisaged
by the law.
Make sure that the electrical system is adequate for the maximum power absorbed and is equipped
with an omnipolar disconnector with class III overvoltage category.
The appliance is supplied with an electric cable already fitted with a plug: in case of replacement, contact a qualified
technician and use only original Rinnai spare parts to avoid invalidating the warranty..
Do not use adatpors, multiple sockets and extensions cords.
The device fullfills the requirements of European Directives:
- “Low voltage” Directive;
- “Elettromagnetic compatibility” Directive.
The boilers are in IPx5D protection class.
2.6.5 RINNAI WIFI CHRONOTHERmOSTAT
The boiler is supplied ready for the use with the Rinnai WiFi chronothermostat. The controller is pre-set to operate by
controlling the flow temperature of the heating system.
To operate, the remote control must remain connected via cable (two wires) to the device, which supplies it electrically
in low voltage: it is possible to extend the supplied electric cable with a cable of the same section.
IMPORTANT
The controller must be installed on an accessible wall, at a height of 1.2-1.5m from the ground; in
a place that is significant for the home, especially if it is used in ‘room-thermostat’ mode.
Avoid installing it in areas where the temperature is >40°C, <-20°C or with a high humidity level,
where it is directly affected by solar light, subjected to splashes of water, to the effect of chemical
agents or fouling (in particular of fatty substances).
The electrical wiring of the remote control must be in good condition: in case of damage or
deterioration it is necessary to replace it.
Do not use electrical conduits already used for high voltage cables (230V): in this case it is
necessary to replace the supplied cable with a suitably shielded cable to avoid electromagnetic
interferences.
WiFi Rinnai chronothermostat installation
Prior to begin the installation, it is necessary to electrically isolate the appliance by disconnecting it from the electrical
socket.
Wall mounted:
•
separate the metal bracket from the controller;
•
use the bracket as template to prepare the holes for the plug (Ø6.0 x
35~40mm);
•
insert the plugs in the holes prepared;
•
fasten the bracket with the screws;
•
fix the two ends of the supplied electric cable to the two poles of the
control (rear part);
•
install the control to the metallic bracket.
Installation in electric box:
•
separate the metal bracket from the controller;
•
fix the bracket to the electric box;
•
fix the two ends of the supplied electric cable to the two poles of the
control (rear part);
•
install the control to the metallic bracket.
Wall clamping
Electric box
Straws
Wall
Component’s seat
Straws