− 18 −
MEASURES WHEN THE SAFETY DEVICE IS OPERATED
This appliance displays information when the safety device is operated. If the dryer
stops during operation, check whether the safety device is operated or not. When
the “CLEAN FILTER” lamp lights together with the failure display, it means the
fi
lter is blocked. The dryer is not unusual when the “CLEAN FILTER” lamp lights
during operation. Clean the
fi
lter after operation. When the safety device is on, the
indicator
fl
ashes and the buzzer sounds 5 times.
(Indication
fl
ash is stopped when
power is switched off)
Indication for the
S a f e t y D e v i c e
Operating
(Lamp flashing)
Cause
Measures
Lint Filter or Back Filter is
blocked by lint.
Clean Filter and restart after
10 mins
Gas valve is not opened.
After Inspection, re-operate.
G a s h o s e i s n o t c o n n e c t e d
properly.
Gas valve is not opened fully.
After Inspection, re-operate.
Lack of oxygen inside room.
Need to ventilate fully and then
re-operate.
Lint Filter or Back Filter is blocked
by lint.
Clean Filter and restart after 10
mins.
Lint Filter or Back Filter is blocked
by lint.
Discharged Duct is blocked.
Too much clothes.
Trouble in the electric system.
Clean Filter and restart after 10
mins.
In case “32” is re-indicated, need
to repair.
Call for repair.
Lack of oxygen for combustion.
Lint Filter or Back Filter is blocked
by lint.
Clean Filter and restart after 10
mins.
In case “90” is re-indicated, need
to repair.
Call for repair.
N u m b e r s o t h e r
t h a n t h e a b o v e
numbers.
Need to repair.
Call for repair.
A l l l a m p s l i g h t
OFF.
Trouble in the electric system.
Need to repair.
Call for repair.
Trouble for over-heat.