12
Ignition
1. Press the control knob for about 3 mm and turn to the left (counter clock-wise) to the “
● ● ●
”
(
MAX)
position.
2 In the event of the burner flames being accidentally extinguished, turn off the burner control and do
not attempt to re-ignite the burner for at least 1 min. If the burner has not lit up after 15 seconds,
stop operating the built-in hob and open the compartment door and/or wait for at least 1 minute
before attempting to ignite the burner again.
3. The flame can be controlled between “
● ● ●
”
(
MAX)
and “
●
”
(
MIN) position, please adjust the flame
slowly.
4. Do not clean the top of the sensor with a hard
brush, as it may damage the sensor.
Flame Extinguishing
1. After the usage, turn the control knob right (clock-wise) to the original “
●
” position and the flame will
be extinguished.
2. After extinguishing of the flame, do not touch the conductive parts of the built-in hob as they may
remain at high temperature.
3. There might be a slight hissing sounds after the extinguishing of the flame.
4. If the built-in hob is not in use, turn off the main gas supply in order to avoid gas leakage or
unnecessary accidents.
How to Handle Safety Device
1. If the flame is extinguish during operation, the flame failure safety device will automatically cut off the
gas within second.
If you notice that the flame has been extinguished, please turn the knob to “
●
” position and do not
attempt re-ignite the burner at least 1 minute.
Max Position
Min Position
6. Operating Instructions
Summary of Contents for RB-3311D-GBS
Page 19: ...19...
Page 20: ...20 http www rinnai com...