Neo RIB2312 installation guide: 12148-A 01-17
|
11
Mantels and surrounds - inbuilt models only
Combustible mantels and surrounds require clearance from the unit to minimise
the risk of fire. Mantels and surrounds, made of combustible materials such as
wood, are allowed providing they are outside the minimum clearances shown.
The Neo gas fireplace is not designed to be built into bookcases.
A
B
C
A
Mantel needs to be a minimum of 400 mm away from the edge of the inner glass.
B
Maximum mantel depth at 400 mm (A) is 250 mm.
C
Surround needs to be a minimum of 400 mm away from the edge of the inner glass.
For every 50 mm of added mantel depth there must be an additional 100 mm of clearance from
the edge of the inner glass.
For example:
M
antel
depth
a
:
clearance
required
300 mm
500 mm
350 mm
600 mm
400 mm
700 mm