Rinnai MC502S Operation & Installation Manual Download Page 17

Rinnai New Zealand

15

Operation Manual

Summary of Contents for MC502S

Page 1: ...l MC 91 Deluxe Kitchen MC 70V Deluxe Bathroom BC 70V This manual applies to the Rinnai Wireless Controller MC502S This manual must be used in conjunction with the Rinnai Water Heater Operation Installation Manual supplied with Rinnai water heaters MC502S Wireless Controllers are compatible only with the Rinnai water heater and other remote controller models shown Refer to the table on page 2 of th...

Page 2: ...NTROLLER INFORMATION 2 USING WIRELESS CONTROLLERS 3 ABOUT THE WIRELESS CONTROLLER 3 HOW TO USE WIRELESS CONTROLLERS 3 TURNING ON THE WIRELESS CONTROLLER 3 ADJUSTING TEMPERATURE 3 TRANSFERRING PRIORITY BETWEEN CONTROLLERS 4 WIRELESS CONTROLLERS BATTERIES 4 TROUBLESHOOTING 5 ERROR CODES 5 SERVICE 5 INSTALLATION MANUAL 6 CONTACT INFORMATION 16 OPERATION MANUAL ...

Page 3: ... operate in the same radio frequency spectrum as many other devices classified as LIPD s such as garage door openers and keyless automobile entry systems Although interference with other LIPD s is unlikely it is not guaranteed interference will not occur Rinnai wireless controllers must not be used in the vicinity of other devices if radio interference with such devices could result in a dangerous...

Page 4: ... obtain water temperatures lower than 37 C simply add cold water The temperature of outgoing hot water is constantly monitored by a built in sensor If the temperature of the outgoing hot water rises to more than 3 C above the selected temperature shown on the digital monitor the burner will automatically go out The In Use indicator will also go out The burner will ignite again once the outgoing ho...

Page 5: ...hot water once a hot water tap is opened ADJUSTING TEMPERATURE Simply press the hot water temp or buttons until the required temperature is displayed on the digital monitor To operate the water heater open any hot water tap This will automatically light the burner providing hot water The In Use indicator will illuminate on the water controller Once the hot water is running if the set temperature i...

Page 6: ...only be able to be selected on the controller used for the kitchen not on controllers used in bathrooms ensuites or toilets This helps minimise the risk of burns The wireless transceiver has been incorrectly assigned if temperatures in excess of 50 C are able to be selected on controllers used in bathrooms toilets and laundries Re assign the wireless transceiver if this is the case See UN ASSIGNIN...

Page 7: ...es service please call 0800 Rinnai 0800 746 624 Rinnai recommends that this appliance be serviced every 3 years CODE FAULT REMEDY Wireless water controller is Out of Range due to distance from transceiver or an obstruction Move wireless water controller or transceiver or remove the obstruction Noticeable reduction in water flow Inlet water filter needs to be cleaned Service call 03 Power interrupt...

Page 8: ...ATION 10 MOUNTING THE TRANSCEIVER 10 CONNECTING COMMUNICATION CABLE TO THE WIRELESS TRANSCEIVER 10 SETTING THE MAXIMUM TEMPERATURE AT THE TRANSCEIVER 10 WIRELESS CONTROLLER INSTALLATION 11 INSTALLING WIRELESS CONTROLLERS 11 INSTALLING MULTIPLE WIRELESS CONTROLLERS 12 TROUBLE SHOOTING WIRELESS CONTROLLERS CHANNEL ASSIGNMENT 12 UN ASSIGNING AND RESETTING WIRELESS CONTROLLERS 12 INSTALLING WIRED AND ...

Page 9: ...is limited to 50 C the maximum temperature that the water heater will deliver is 50 C In this case 55 C will be displayed on the wireless Master Controller until a tap is opened after which the display will revert to 50 C The remaining controllers are designated sub controllers and are for use in bathrooms toilets and laundries The temperature limit for all Sub controllers is always 50 C to minimi...

Page 10: ...ontrollers must be installed at least 400 mm above the highest part of a sink basin or bath The transceiver comes supplied with a 1 5m communications cable The transceiver s antenna is located in the top For the best results mount the transceiver so the top of the transceiver is higher than the top of the water heater If the transceiver is mounted to the side or below the water heater signal stren...

Page 11: ...a qualified and licensed tradesperson 1 Isolate the electric power supply by switching the power point off and removing the power plug of the water heater from the electric power socket 2 Remove the retaining screw of the Quick Connect cable connector at the base of the appliance 3 Swing the Quick Connect cable connector door open and thread the cable through the weather seal of the cable access h...

Page 12: ...r tightening of fixings as this may cause damage DO NOT use powered tools to tighten fixings CONNECTING COMMUNICATION CABLE TO THE WIRELESS TRANSCEIVER 1 With the electric power supply still isolated unscrew the transceiver access cover to reveal control keypad and terminals 2 Thread the transceiver cable through the cable clamp allowing sufficient cable length so that the sheath of the cable can ...

Page 13: ...rom it s wall mounting bracket Open the battery compartment with a anti clockwise turn of the locks using a coin or a suitable screw driver Insert the batteries observing the correct polarity Close the battery compartment with a clockwise turn of the locks 4 After battery installation the wireless controller will momentarily display an initialisation screen A which will then switch to screen B or ...

Page 14: ...AND WIRELESS CONTROLLERS When installing combinations of both wired and wireless controllers all wired controllers MUST BE connected before the wireless controllers are assigned to a transceiver channel Refer to page 1 to confirm the maximum number and combination of water controllers that can be fitted Wired water controllers can ONLY be added to an existing wireless installation when All wireles...

Page 15: ...e of the transceiver or when an object is obstructing the radio signal Wireless controllers should be positioned such that the signal strength indicator displays at least 2 bars next to the antenna symbol during installation Signal strength varies with atmospheric and other conditions If the signal strength is weaker than 2 bars during installation there may be other times when the signal is too w...

Page 16: ...Rinnai New Zealand 14 Operation Manual NOTES ...

Page 17: ...Rinnai New Zealand 15 Operation Manual ...

Page 18: ...Rinnai NZ Ltd PO Box 24068 Royal Oak Auckland New Zealand 0800 Rinnai 0800 746 624 www rinnai co nz info rinnai co nz U284 0172 Printed in Japan YYYY MM U284 0172 㻓㻙㻓㻓㻓㻓㻔㻕㻘㻔㻗㻗㻛㻖 CONTACT INFORMATION ...