32
2.9 CONTROL PANEL PROGRAMMING
QUESTION
?
1
Are there four control panels connected (control panel + remote controllers)?
NO:
If there are up to 3 control panels connected, go to question 2.
YES:
You need to activate the fourth controller as follows:
STEP 1:
On the ‘Master’ controller only, press and hold the ‘Priority’ and ‘On/Off’ buttons
simultaneously (see Fig. 1) until a ‘beep’ is heard (approximately 5 seconds).
STEP 2:
Check that the display on all four controllers is lit and displaying a temperature
when ‘switched on’.
If any one of the controllers displays two dashes (see Fig. 2) repeat from STEP 1.
This completes the activation procedure for the fourth controller, you may ignore
Question 2.
QUESTION
?
2
Do you want hot water temperature limited to 50°C?
YES:
No further action required.
NO:
You need to unlock the ‘Master’ remote to achieve high temperatures.
STEP 1:
On the ‘Master’ controller only, press and hold the ‘Priority’ and ‘On/Off’ buttons
simultaneously (Fig. 3) until a ‘beep’ is heard (approximately 5 seconds).
STEP 2:
When the ‘Master’ controller is switched on, it should be possible to select
temperatures higher than 50°C. If not, repeat STEP 1.
NOTE
If the ‘Master’ controller is changed to a new one, repeat the procedure from ‘
STEP 1
’ (question
2) on the new controller.
If the ‘Master’ controller is switched with a new controller previously installed (e.g. the one in the
laundry), repeat the procedure from ‘
STEP 1
’ (question 2) on both controllers.
F i g . 1
F i g . 2
F i g . 3