31
Installation procedure (appliance side):
CAUTION
DO NOT
attempt to connect cables to the water heater unless the electric power is switched ‘off ’
otherwise damage to electrical components may occur
.
1.
Isolate the electric power supply by switching the
power point off and removing the power plug of the
water heater from the electric power socket;
2.
Remove the front panel: remove the gray plastic
side strips and unscrew the 4 fi xing screws of the
panel;
3.
Pass suffi cient cable through the hole in the casing
(Fig. 1); connect the terminal end to the PCB
C
(Fig. 2);
4.
Connect the other terminal of the cable
A
to the
remote control connector
B
(Fig. 3);
5.
Fix the front panel back.
When connecting more remote controllers it is necessary to cut the connectors
A
and
B
, and to use a common
electrical terminal block (optional).
WARNING
The additional remote controls must be electrically connected in parallel: a series connection
causes the system to malfunction and can damage the components of the appliance.
2.8.2 STANDARD REMOTE CONTROLLER (MC-601) INSTALLATION
1.
Determine the most suitable position.
2.
Mark and drill 3 holes (mounting and cable access) for remote controller dimensions.
3.
When running cable through the access hole ensure the connector end of the cable is located nearest to the
remote controller (Fig. 1).
4.
Carefully remove the cover plates from the remote controller, using a screw driver (Fig. 2).
5.
Connect the cable to the remote controller. Feed any excess cable lengths into the wall cavity to avoid the
pinching of cables between the wall and the remote controller.
6.
Fix the remote controller to the wall using the appropriate fi xings (Fig. 3).
7.
Remove protective fi lm from the controller face and replace the cover plates (Fig. 4).
Connector
Controller Cable
Screws
Film
F i g . 1
F i g . 2
F i g . 3
F i g . 4
Cover
Plates
Fig. 1
Fig. 2
Fig. 3
B
A
B
A
A
C