Introduction
The Rinnai Infinity hot water units represents the latest
technology in continuous flow, temperature controlled hot water.
Features
•
The Rinnai
Infinity 16i will
NEVER RUN OUT
of hot water. As long as electricity,
water, and gas supplies are connected, hot water is available when hot water taps
are open.
•
Built into the main micro-processor is the facility to
LIMIT THE MAXIMUM TEM-
PERATURE
of the hot water supplied. The water temperature may be set to vari-
ous temperatures. This is particularly useful when the hot water unit is installed
where young children or the infirm may be using the hot water. If required, the tem-
perature can be changed via the control pad on the front of the unit or with a local-
ised controller. For further information, please contact Rinnai.
•
Rinnai Infinity internal units are powered flue appliances. This makes them
COM-
PACT
, saving both floor and wall space.
•
The temperature of outgoing hot water is
CONSTANTLY MONITORED
by a
BUILT-IN SENSOR
. If the temperature of the outgoing hot water rises to more than
55°C the burner is shut OFF and only turned ON again when the temperature falls
to below the selected temperature.
•
The burner lights automatically when the hot water tap is opened, and extinguishes
when the tap is closed.
IGNITION IS ELECTRONIC
, so there is no pilot light. When
the hot water tap is off, no gas is used.
•
The 16i has a built in controller on the front of the unit for easy control. Two addi-
tional external temperature controllers can be mounted remotely from the heater.
This offers the following additional features:
Localised temperature setting.
Diagnostic
message.
Error
Codes.
•
Temperatures selected at the controllers are retained in the
SYSTEM MEMORY
when the controller gives up priority or the system is turned off. Temperatures over
55
0
C will revert to 55
0
C when power and/or priority is regained.
•
Operating
NOISE LEVEL IS VERY LOW
.
•
ERROR MESSAGES ARE DISPLAYED
on the Temperature Controllers, assisting
with service.
•
FROST PROTECTION
device built in as standard.
Summary of Contents for FUA-E
Page 1: ......
Page 5: ...5 Glossary of Terms and Symbols ...
Page 9: ...9 Dimensions ...
Page 11: ...11 Structure Diagram ...
Page 17: ...17 Gas Conversion Procedure ...
Page 18: ...18 Gas Conversion Procedure ...
Page 25: ...25 Operational Flow Chart ...
Page 26: ...26 Time Charts ...
Page 39: ...39 Diagnostic Checks Fault Finding Chart ...
Page 40: ...40 Fault Finding Chart ...
Page 41: ...41 Fault Finding Chart ...
Page 42: ...42 Fault Finding Chart ...
Page 43: ...43 Fault Finding Chart ...
Page 44: ...44 Fault Finding Chart ...
Page 45: ...45 Fault Finding Chart ...
Page 46: ...46 Wiring Diagram ...
Page 49: ...49 Dismantling for Service ...
Page 50: ...50 Dismantling for Service ...
Page 51: ...51 Dismantling for Service ...
Page 52: ...52 Dismantling for Service ...
Page 53: ...53 Dismantling for Service ...
Page 54: ...54 Dismantling for Service ...
Page 55: ...55 Dismantling for Service ...
Page 56: ...56 Exploded Diagram ...
Page 57: ...57 Exploded Diagram ...
Page 58: ...58 Exploded Diagram ...
Page 59: ...59 Exploded Diagram ...
Page 60: ...60 Exploded Diagram ...
Page 61: ...61 Parts List ...
Page 62: ...62 Parts List ...
Page 63: ...63 Parts List ...
Page 64: ...64 Parts List ...
Page 65: ...65 Letter of Compliance ...
Page 66: ...66 CE Certificate ...
Page 67: ......